quiko QK-CE220RL4 User Manual Download Page 8

www.quikoitaly.com

 

7 of 12

There are two sensor operating mode: Obstacle Detection and Limit switch. They are described in the table below: 

Obstacle Detection

Limit Switch

In this operating mode the motor changes direction. If the direction was 
closure, the gate opens completely. If the direction was opening, the 
gate closes for 2 seconds. After this time, it stops. A start command will 
restart the closing. This functionality is active once per working cycle. 
For additional times during the cycle the sensor works as a limit switch.

In this operating mode the motor finishes the
working phase: from Opening to Pause, from 
Closing to Stand by.

The operating mode depends on the working phase and parameters programming. The working phases are: opening, 
opening slowdown, closing, closing slowdown. The relevant parameters are: 

A2

A7

A8

E5

E6

.

If 

A7

 is set to 

no

 the sensor is disabled during the standard working time. This means that it doesn't work in any 

operating mode during the standard working time (

A1

).  

If 

A8

 is set to 

no

 or 

A2

 is equal to 

00

 the sensor is disabled during the slowdown working time. This means 

that it doesn’t work in any operating mode during the slowdown working time (

A2

).   

If the limit switches inputs are installed (

E5

=

SI

 and 

E6

=

SI

): the sensor works in obstacle detection mode. 

If the opening limit switch input is not installed (

E6

=

no

) and the opening is in progress:  the sensor works in 

obstacle detection mode during the standard working time (

A1

). During the slowdown (

A2

) the sensor works in 

limit switch mode. 

If the opening limit switch input is not installed (

E6

=

no

) and the slowdown phase is disabled (

A2

 = 

00

): the 

sensor works in limit switch mode during the opening. 

If the closing limit switch input is not installed (

E5

=

no

) and the closing is in progress: the sensor works in 

obstacle detection mode during the standard working time (

A1

). During the slowdown (

A2

) the sensor works in 

limit switch mode. 

If the closing limit switch input is not installed (

E5

=

no

) and the slowdown phase is disabled (

A2

 = 

00

): the 

sensor works in limit switch mode during the closing.  

If both limit switches inputs are not installed (

E5

=

no

 and 

E6

=

no

): the sensor works in obstacle detection 

mode during the standard working time(

A1

). During the slowdown working time (

A2

) the sensor works in limit 

switch mode. 

If both limit switches inputs are not installed (

E5

=

no

 and 

E6

=

no

) and the slowdown phase is disabled

 (

A2

 = 

00

): the sensor works in limit switch mode.

Obstacle Detection

Limit Switch

Disabled

Opening

E6

 = 

SI

or

E6

 = 

no

 

and

 

A2

 enabled

E6

 = 

no

 

and

 

A2

 disabled

A7

 = 

no

 

Opening 

 Slowdown

E6

 = 

SI

 

E6

 = 

no

A8

 = 

no

or

A2

 disabled

Closing

E5

 = 

SI

or

E5

 = 

no

 

and

 

A2

 enabled

E5

 = 

no

 

and

 

A2

 disabled 

A7

 = 

no

Closing

  Slowdown 

E5

 = 

SI

 

E5

 = 

no

A8

 = 

no

or

A2

 disabled

OPERATING

MODE

WORKING

PHASE

SENSOR OPERATING MODE

Summary of Contents for QK-CE220RL4

Page 1: ...can be used also for the same version of control board for 110V motors Item code of the board becomes QK CE110RL4 and all 230 220V within this manual to be read as 110V F1 fuse is 10A QK CE110RL4 control board is equipped with a 110V transformer V14 2016 SW HS2117 E N G L I S H ...

Page 2: ...pins IMPORTANT RESETTABLE FUSES AFTER SHORT CIRCUIT TURN OFF THE CONTROL BOARD REMOVE THE SHORT CIRCUIT WAIT FOR 60 SECONDS OR MORE TURN ON THE CONTROL BOARD F4 F5 EXTERNAL PHOTOCELL 24 VDC POWER SUPPLY TYPE PIN CONFIG PARAMETER TRANSMITTER 8 10 N C X X E3 RECEIVER 3 8 INTERNAL PHOTOCELL 24 VDC POWER SUPPLY TYPE PIN CONFIG PARAMETER TRANSMITTER 8 10 N C X X E4 RECEIVER 4 8 OTHER INPUTS TYPE PIN CO...

Page 3: ...ng opening and closing for the standard working time the display shows the motor stress A8 NO DISABLED 99 NO 0 Slowdown obstacle detection threshold During opening and closing for the slowdown working time the display shows the motor stress General Functions DISPLAY DEFAULT C MAX D MIN DESCRIPTION F0 10 sec 99 sec 00 sec Pause time To disable hold down C button until display shows 5t F1 7 sec A1 s...

Page 4: ...taly com 3 of 12 Antenna Flashing lamp External photocells INTERNAL OF THE PROPERTY Internal photocells Motor TYPICAL INSTALLATION OPTIONAL QK AN433_V4 L bracket is not available on QK LUX24E flashing lamp model ...

Page 5: ...11 12 24V 24V COM 1 2 3 4 5 6 7 8 9 10 11 12 24V 24V COM 1 2 3 4 5 6 7 8 9 10 11 12 24V 24V COM 1 2 3 4 5 6 7 8 9 10 11 12 24V 24V COM 1 2 3 4 5 6 7 8 9 10 11 12 JUNCTION 1 2 3 4 5 6 7 8 9 10 11 12 JUNCTION 1 2 3 4 5 6 7 8 9 10 11 12 Set E4 to no Set E3 to no 4 D DISABLED BY SOFTWARE PHOTOCELLS RECEIVER 4 A PHOTOCELLS TRANSMITTER WITHOUT PHOTO TEST FUNCTION 4 B PHOTOCELLS TRANSMITTER WITH PHOTO TE...

Page 6: ...e the display shows only the most important input The order from the most important to the least important input is stop 5t internal and external photocells FH external photocells tC internal photocells tA start Go pedestrian start PE open only oP close only CL Opening and Closing limit switches 1H Closing limit switch N C FC Opening limit switch N C FA Closing limit switch N O LC Opening limit sw...

Page 7: ...ce with its programming as described in SENSOR OPERATING MODE see page 7 When the motor is on and the standard working time is in progress the control board display shows the motor stress You can use this value as a feedback value 00 is the minimum and 99 is the maximum The maximum value depends on the motor and can be lower than 99 To disable the obstacle detection sensor during the standard work...

Page 8: ...tection mode If the opening limit switch input is not installed E6 no and the opening is in progress the sensor works in obstacle detection mode during the standard working time A1 During the slowdown A2 the sensor works in limit switch mode If the opening limit switch input is not installed E6 no and the slowdown phase is disabled A2 00 the sensor works in limit switch mode during the opening If ...

Page 9: ...e closing If the external photocell is activated the control board stops the closing and starts the opening The activation of the internal photocell doesn t have any effect instead F8 no REVERSE MODE During the opening While the internal photocell is activated the control board stops the opening When the internal photocell is deactivated the control board continues the opening The activation of th...

Page 10: ... Working Cycle The motor works for a total time of A1 plus A2 seconds during the opening and the closing r2 Stop The stop function stops the gate r3 Pedestrian The pedestrian function begins a Pedestrian Working Cycle The motor works for a total time of F1 seconds during the opening and closing The slowdown phase is skipped during the opening and executed during the closing The slowdown time is au...

Page 11: ...nd activated the display shows tC E3 Input4 InternalPhotocell E4 no DISABLED E4 tA ENABLED The input 4 is configurable as Disabled no or Internal Photocell The Internal Photocell function matches a normally closed contact t is always advisable to install the internal photocell device During the installation phase it may be useful to disable E4 When the photocell device is wired to the terminal blo...

Page 12: ...ivided into 3 steps A1 A2 and F0 In each step the linked parameter is programmed During the whole programming procedure the obstacle detection sensor is disabled P1 __ The control board is ready to start the motor working time programming To go to A1 press any start input A1 The standard working time of the motor A1 is being programmed The gate is opening To change the programming phase If opening...

Page 13: ...0RL4 complies with the main safety requirements issued by the following directives Radio Sets 1999 05 EC Low Voltage 2006 95 EC Electromagnetic Compatibility 2004 108 EC and any revisions thereof and complies with the provisions that implement said directives in the National Legislation of the Country of destination where the products are to be used Sossano 10 11 2012 2 ...

Page 14: ......

Page 15: ......

Page 16: ......

Page 17: ...V14 201 SW HS211 I T A L I A N O SCHEDA DI COMANDO PER 1 MOTORE MONOFASE 230V ac guida all i n s t a l l a z i o n e QK CE220RL4 433 92 MHz 230V PLUG PLAY MEMORIA TX ...

Page 18: ...iera FOTOCELLULA ESTERNA ALIMENTAZIONE 24 VDC TIPO PIN PARAMETRO TRASMETTITORE 8 10 N C X X E3 RICEVITORE 3 8 FOTOCELLULA INTERNA ALIMENTAZIONE 24 VDC TIPO PIN PARAMETRO TRASMETTITORE 8 10 N C X X E4 RICEVITORE 4 8 ALTRI INGRESSI TIPO PIN PARAMETRO START SOLO APRI SOLO CHIUDI N A 1 8 E1 PEDONALE SOLO APRI SOLO CHIUDI N A 7 8 E7 STOP N C 2 8 E2 FINECORSA CHIUSURA N C 5 8 E5 FINECORSA APERTURA N C 6...

Page 19: ...Chiusura N C LC Finecorsa Chiusura N A E6 FA no Disabilitato FA Finecorsa Apertura N C LA Finecorsa Apertura N A E7 PE no Disabilitato PE Start Pedonale N A oP Solo Apri N A CL Solo Chiudi N A N A Normalmente Aperto N C Normalmente Chiuso FUNZIONI DI CORTESIA DISPLAY DISPLAY C DESCRIZIONE d0 no Imposta Per ripristinare il default mantenere premuto il tasto C finché il display non mostra P1 __ X Qu...

Page 20: ...nna Lampeggiatore Fotocellule esterne INTERNO DELLA PROPRIETÀ Fotocellule interne Motore INSTALLAZIONE TIPO ALL INTERNO DEL CONTENITORE ANTENNA OPTIONAL QK AN433_V4 Staffa a L non disponibile nella versione QK LUX24E del lampeggiante ...

Page 21: ...4V COM 1 2 3 4 5 6 7 8 9 10 11 12 24V 24V COM 1 2 3 4 5 6 7 8 9 10 11 12 24V 24V COM 1 2 3 4 5 6 7 8 9 10 11 12 PONTICELLO 1 2 3 4 5 6 7 8 9 10 11 12 PONTICELLO 1 2 3 4 5 6 7 8 9 10 11 12 Impostare E4 a no Impostare E3 a no 4 D DISABILITAZIONE SOFTWARE RICEVITORE FOTOCELLULE 4 A TRASMETTITORE FOTOCELLULE SENZA FUNZIONE DI TEST 4 B TRASMETTITORE FOTOCELLULE CON FUNZIONE DI TEST 4 C DISABILITAZIONE ...

Page 22: ...iave è attivato quando la chiave viene girata Tutte queste azioni sono riconosciute dalla centrale di controllo che mostra il cambiamento sul display Quando più ingressi sono attivati contemporaneamente la centrale di controllo mostra quello a priorità più alta La priorità dalla più alta alla più bassa è la seguente Stop 5t Fotocellule Esterne e Fotocellule Interne FH tC Fotocellule Esterne tA Fot...

Page 23: ...e una decisione in accordo con la programmazione effettuata come descritto in OPERATIVITÀ DEL SENSORE pagina 7 Durante il tempo di lavoro normale A1 il display mostra il valore dello sforzo del motore 00 è il valore minimo 99 quello massimo Il valore massimo dipende dal motore e può essere minore di 99 Per disabilitare il sensore ostacoli in modalità normale impostare A7 no Per impostare A7 no pre...

Page 24: ...na nella modalità RILEVAZIONE OSTACOLI Se il fine corsa di apertura non è installato E6 no e l apertura è in corso il sensore funziona nella modalità RILEVAZIONE OSTACOLI durante il tempo di lavoro normale A1 Durante il tempo di rallentamento A2 il sensore funziona nella modalità FINE CORSA Se il fine corsa di apertura non è installato E6 no e il tempo di rallentamento è disabilitato A2 00 il sens...

Page 25: ...ffetto Durante la chiusura Se le fotocellule esterne sono attivate la centrale blocca la chiusura e avvia l apertura L attivazione delle fotocellule interne non ha ha effetto F8 no LOGICA BATTENTE Durante l apertura Finché le fotocellule interne sono attivate la centrale sospende l apertura Quando le fotocellule vengono disattivate l apertura riprende L attivazione delle fotocellule esterne non ha...

Page 26: ...Se la memoria è piena i display visualizzeranno FF al momento del salvataggio r1 funzione di start La funzione di start avvia un ciclo di lavoro standard Il motore lavora per un tempo totale di A1 più A2 secondi durante l apertura e la chiusura r2 funzione di stop La funzione di stop ferma il cancello r3 funzione di pedonale La funzione di pedonale avvia un ciclo di lavoro pedonale il motore lavor...

Page 27: ...resso4 FotocellulaApertura E4 no DISABILITATO E4 tA ABILITATO L ingresso 4 è configurabile con queste funzioni Disabilitato no o Fotocellula Apertura tA La funzione Fotocellula Apertura è associata ad un contatto normalmente chiuso Durante la fase di installazione può essere utile disabilitare l ingresso 4 Quando le fotocellule sono collegate all ingresso 4 la centrale lo rileva e imposta E4 tA Fo...

Page 28: ...er avviare la procedura di acquisizione sequenziale Per passare al passo A1 premere un ingresso di start A1 Si sta acquisendo il Tempo Normale del motore A1 Il cancello si apre Per passare al passo di programmazione successivo Se il fine corsa d apertura non è installato E6 no Per passare al passo A2 premere un ingresso di start Se il fine corsa d apertura è installato E6 SI Per passare al passo A...

Page 29: ...ndo QK CE220RL4 è conforme ai requisiti essenziali di sicurezza delle direttive Apparecchiature Radio 1999 5 CE Bassa Tensione 2006 95 CE C 2004 108 CE macchina Sossano 10 11 2012 Via Seccalegno 19 36040 Sossano VI Italia Il Legale Rappresentante Luca Borinato ...

Page 30: ......

Page 31: ......

Page 32: ...facturer can technically improve the quality of its products without any prior notice Quiko Italy Via Seccalegno 19 36040 Sossano VI Italy Tel 39 0444 785513 Fax 39 0444 782371 info quiko biz www quikoitaly com ...

Reviews: