BUTTONS

@

 A

Scrolls menu from 

A1

 to 

P2

@

 B

Scrolls menu from

 

P2

 to 

A1

@

 C

Increases value or set

 

SI

 (

means: ON or ENABLED).

@

 D

Decreases value or set

 

no

 

(

means: OFF or DISABLED).

Terminal Block Settings

DISPLAY  DEFAULT

@

 

C

@

 

D

DESCRIPTION

E1

Go

   

no

  = 

Disabled.

Go

  = 

Start  

N.O

.

oP

  = 

Open only 

N.O

.

 

CL

  = 

Close only 

N.O

.

E2

no

   

no

  = 

Disabled.

St

  = 

Stop 

N.C

.

E3

no

   

no

  = 

Disabled.

tC

  = 

External photocell 

N.C

.

E4

no

   

no

  = 

Disabled.

tA

  = 

Internal photocell 

N.C

  

E5

FC

   

no

  = 

Disabled.

FC

  = 

Closing limit switch 

N.C

.

LC

  = 

Closing limit switch 

N.O

.

E6

FA

   

no

  = 

Disabled.

FA

  = 

Opening limit switch 

N.C

.

LA

  = 

Opening limit switch 

N.O

.

E7

PE

   

no

  =

 Disabled.

PE

  =

 Pedestrian 

N.O

.

 

oP

  =

 Open only 

N.O

.

CL

  =

 Close only 

N.O

.

N.O. → Normally Open                N.C. → Normally Closed  

www.quikoitaly.com

 

2 of 12

INPUT/OUTPUT CONNECTIONS

FUNCTION SUMMARY

Display Report

St

Stop.

FH

External pho 
Internal photocell.

tC

External photocell.

tA

Internal photocell.

oP

Open Only.

CL

Close Only.

1H

Opening limit 
Closing limit switch.

FA

Opening limit switch.
Normally Closed.

FC

Closing limit switch.
Normally Closed.

LA

Opening limit switch.
Normally Open.

LC

Closing limit switch.
Normally Open.

L2

Recovery Loop is 
running.

-

Remote key is 
pressed.

1t

Photocells test error.

7A

Motor has detected
an obstacle during the
standard working 
time.

8A

Motor has detected 
an obstacle during the
slowdown working 
time.

9A

Motor is in thermal 
protection state.

FF

The radio memory is 
full.

Motor Setting

DISPLAY  DEFAULT

@

 

C

MAX

@

 

D

MIN

DESCRIPTION

A1

30

sec

99

sec

00

sec

Standard working time

A2

10

sec

99

sec

00

sec

Slowdown working time

A3

0.1
sec

1.5
sec

0.1
sec

Start up time 

A5

7

10

1

Standard force

A6

8

10

1

Slowdown force

A7

NO

(DISABLED)

99 - NO

0

Standard obstacle 
detection threshold. 
During opening and 
closing, for the standard 
working time, the display
shows the motor stress.

A8

NO

(DISABLED)

99 - NO

0

Slowdown obstacle 
detection threshold. 
During opening and 
closing, for the slowdown
working time, the display
shows the motor stress.

General Functions

DISPLAY  DEFAULT

@

 

C

MAX

@

 

D

MIN

DESCRIPTION

F0

10

sec

99

sec

00

sec

Pause time.
To disable hold down 

@

 

C

 

button until display shows

5t

F1

7

sec

A1

sec

0

sec

Pedestrian working time.
It is the motor working 
time during a pedestrian 
working cycle. 

F2

0.0
sec

1.0
sec

0.0
sec

Kick back function during 
closing.

F3

0.0
sec

5.0
sec

00

sec

Pre-blinking time

F4

NO

(OFF)

SI

(ON)

NO

(OFF)

Kick back function during 
opening.

F5

NO

(OFF)

SI

(ON)

NO

(OFF)

Step-by-step function

F6

NO

(OFF)

SI

(ON)

NO

(OFF)

Community mode 

F8

SI

SI

NO

Photocells logic:

SI

Standard logic

no

Reverse logic 

L1

00

min

10

min

00

min

Cold winter function. This 
function is useful in 
countries where the 
winter is extremely cold.  

L2

NO

(OFF)

SI

(ON)

NO

(OFF)

Recovery loop function

This function is useful to 
avoid motor lock due to 
gate inertia.  

t1

NO

(OFF)

SI

(ON)

NO

(OFF)

Photocells test

t2

SI

(ON)

SI

(ON)

NO

(OFF)

Motor thermal protection
test

Courtesy Functions

DISPLAY 

DISPLAY

@

 

C

DESCRIPTION

d0

no

Set Up

To restore default setting hold 
down 

@

 

C

 button until display 

shows 

--

P1

__

X

When a start command is 
received the control board 
starts an automatic procedure 
to acquire the gate working 
times.

Radio Functions

DISPLAY 

DISPLAY

@

 

C

DESCRIPTION

r0

1

...

2

...

Delete

To erase a code:
Hold down

 

@

 

C

 

button on the 

selected

 

code until the display 

turns off

 

**

r1

=_

Save

To save a remote key: 
Hold down a remote key. When 
the display shows

 

_

push 

down

 

@

 

C

 

b

utton on the control 

board. 

The control board holds up 

to 99 codes.

r1

Start

r2

Stop

r3

Pedestrian start

r4

Fast closure start

r2

=_

Save

r3

=_

Save

r4

=_

Save

r5

no

Delete

To erase all codes:
Hold down

 

@

 

button

 

until 

display

 

stops flashing 

SI

Summary of Contents for QK-CE220RL4

Page 1: ...can be used also for the same version of control board for 110V motors Item code of the board becomes QK CE110RL4 and all 230 220V within this manual to be read as 110V F1 fuse is 10A QK CE110RL4 control board is equipped with a 110V transformer V14 2016 SW HS2117 E N G L I S H ...

Page 2: ...pins IMPORTANT RESETTABLE FUSES AFTER SHORT CIRCUIT TURN OFF THE CONTROL BOARD REMOVE THE SHORT CIRCUIT WAIT FOR 60 SECONDS OR MORE TURN ON THE CONTROL BOARD F4 F5 EXTERNAL PHOTOCELL 24 VDC POWER SUPPLY TYPE PIN CONFIG PARAMETER TRANSMITTER 8 10 N C X X E3 RECEIVER 3 8 INTERNAL PHOTOCELL 24 VDC POWER SUPPLY TYPE PIN CONFIG PARAMETER TRANSMITTER 8 10 N C X X E4 RECEIVER 4 8 OTHER INPUTS TYPE PIN CO...

Page 3: ...ng opening and closing for the standard working time the display shows the motor stress A8 NO DISABLED 99 NO 0 Slowdown obstacle detection threshold During opening and closing for the slowdown working time the display shows the motor stress General Functions DISPLAY DEFAULT C MAX D MIN DESCRIPTION F0 10 sec 99 sec 00 sec Pause time To disable hold down C button until display shows 5t F1 7 sec A1 s...

Page 4: ...taly com 3 of 12 Antenna Flashing lamp External photocells INTERNAL OF THE PROPERTY Internal photocells Motor TYPICAL INSTALLATION OPTIONAL QK AN433_V4 L bracket is not available on QK LUX24E flashing lamp model ...

Page 5: ...11 12 24V 24V COM 1 2 3 4 5 6 7 8 9 10 11 12 24V 24V COM 1 2 3 4 5 6 7 8 9 10 11 12 24V 24V COM 1 2 3 4 5 6 7 8 9 10 11 12 24V 24V COM 1 2 3 4 5 6 7 8 9 10 11 12 JUNCTION 1 2 3 4 5 6 7 8 9 10 11 12 JUNCTION 1 2 3 4 5 6 7 8 9 10 11 12 Set E4 to no Set E3 to no 4 D DISABLED BY SOFTWARE PHOTOCELLS RECEIVER 4 A PHOTOCELLS TRANSMITTER WITHOUT PHOTO TEST FUNCTION 4 B PHOTOCELLS TRANSMITTER WITH PHOTO TE...

Page 6: ...e the display shows only the most important input The order from the most important to the least important input is stop 5t internal and external photocells FH external photocells tC internal photocells tA start Go pedestrian start PE open only oP close only CL Opening and Closing limit switches 1H Closing limit switch N C FC Opening limit switch N C FA Closing limit switch N O LC Opening limit sw...

Page 7: ...ce with its programming as described in SENSOR OPERATING MODE see page 7 When the motor is on and the standard working time is in progress the control board display shows the motor stress You can use this value as a feedback value 00 is the minimum and 99 is the maximum The maximum value depends on the motor and can be lower than 99 To disable the obstacle detection sensor during the standard work...

Page 8: ...tection mode If the opening limit switch input is not installed E6 no and the opening is in progress the sensor works in obstacle detection mode during the standard working time A1 During the slowdown A2 the sensor works in limit switch mode If the opening limit switch input is not installed E6 no and the slowdown phase is disabled A2 00 the sensor works in limit switch mode during the opening If ...

Page 9: ...e closing If the external photocell is activated the control board stops the closing and starts the opening The activation of the internal photocell doesn t have any effect instead F8 no REVERSE MODE During the opening While the internal photocell is activated the control board stops the opening When the internal photocell is deactivated the control board continues the opening The activation of th...

Page 10: ... Working Cycle The motor works for a total time of A1 plus A2 seconds during the opening and the closing r2 Stop The stop function stops the gate r3 Pedestrian The pedestrian function begins a Pedestrian Working Cycle The motor works for a total time of F1 seconds during the opening and closing The slowdown phase is skipped during the opening and executed during the closing The slowdown time is au...

Page 11: ...nd activated the display shows tC E3 Input4 InternalPhotocell E4 no DISABLED E4 tA ENABLED The input 4 is configurable as Disabled no or Internal Photocell The Internal Photocell function matches a normally closed contact t is always advisable to install the internal photocell device During the installation phase it may be useful to disable E4 When the photocell device is wired to the terminal blo...

Page 12: ...ivided into 3 steps A1 A2 and F0 In each step the linked parameter is programmed During the whole programming procedure the obstacle detection sensor is disabled P1 __ The control board is ready to start the motor working time programming To go to A1 press any start input A1 The standard working time of the motor A1 is being programmed The gate is opening To change the programming phase If opening...

Page 13: ...0RL4 complies with the main safety requirements issued by the following directives Radio Sets 1999 05 EC Low Voltage 2006 95 EC Electromagnetic Compatibility 2004 108 EC and any revisions thereof and complies with the provisions that implement said directives in the National Legislation of the Country of destination where the products are to be used Sossano 10 11 2012 2 ...

Page 14: ......

Page 15: ......

Page 16: ......

Page 17: ...V14 201 SW HS211 I T A L I A N O SCHEDA DI COMANDO PER 1 MOTORE MONOFASE 230V ac guida all i n s t a l l a z i o n e QK CE220RL4 433 92 MHz 230V PLUG PLAY MEMORIA TX ...

Page 18: ...iera FOTOCELLULA ESTERNA ALIMENTAZIONE 24 VDC TIPO PIN PARAMETRO TRASMETTITORE 8 10 N C X X E3 RICEVITORE 3 8 FOTOCELLULA INTERNA ALIMENTAZIONE 24 VDC TIPO PIN PARAMETRO TRASMETTITORE 8 10 N C X X E4 RICEVITORE 4 8 ALTRI INGRESSI TIPO PIN PARAMETRO START SOLO APRI SOLO CHIUDI N A 1 8 E1 PEDONALE SOLO APRI SOLO CHIUDI N A 7 8 E7 STOP N C 2 8 E2 FINECORSA CHIUSURA N C 5 8 E5 FINECORSA APERTURA N C 6...

Page 19: ...Chiusura N C LC Finecorsa Chiusura N A E6 FA no Disabilitato FA Finecorsa Apertura N C LA Finecorsa Apertura N A E7 PE no Disabilitato PE Start Pedonale N A oP Solo Apri N A CL Solo Chiudi N A N A Normalmente Aperto N C Normalmente Chiuso FUNZIONI DI CORTESIA DISPLAY DISPLAY C DESCRIZIONE d0 no Imposta Per ripristinare il default mantenere premuto il tasto C finché il display non mostra P1 __ X Qu...

Page 20: ...nna Lampeggiatore Fotocellule esterne INTERNO DELLA PROPRIETÀ Fotocellule interne Motore INSTALLAZIONE TIPO ALL INTERNO DEL CONTENITORE ANTENNA OPTIONAL QK AN433_V4 Staffa a L non disponibile nella versione QK LUX24E del lampeggiante ...

Page 21: ...4V COM 1 2 3 4 5 6 7 8 9 10 11 12 24V 24V COM 1 2 3 4 5 6 7 8 9 10 11 12 24V 24V COM 1 2 3 4 5 6 7 8 9 10 11 12 PONTICELLO 1 2 3 4 5 6 7 8 9 10 11 12 PONTICELLO 1 2 3 4 5 6 7 8 9 10 11 12 Impostare E4 a no Impostare E3 a no 4 D DISABILITAZIONE SOFTWARE RICEVITORE FOTOCELLULE 4 A TRASMETTITORE FOTOCELLULE SENZA FUNZIONE DI TEST 4 B TRASMETTITORE FOTOCELLULE CON FUNZIONE DI TEST 4 C DISABILITAZIONE ...

Page 22: ...iave è attivato quando la chiave viene girata Tutte queste azioni sono riconosciute dalla centrale di controllo che mostra il cambiamento sul display Quando più ingressi sono attivati contemporaneamente la centrale di controllo mostra quello a priorità più alta La priorità dalla più alta alla più bassa è la seguente Stop 5t Fotocellule Esterne e Fotocellule Interne FH tC Fotocellule Esterne tA Fot...

Page 23: ...e una decisione in accordo con la programmazione effettuata come descritto in OPERATIVITÀ DEL SENSORE pagina 7 Durante il tempo di lavoro normale A1 il display mostra il valore dello sforzo del motore 00 è il valore minimo 99 quello massimo Il valore massimo dipende dal motore e può essere minore di 99 Per disabilitare il sensore ostacoli in modalità normale impostare A7 no Per impostare A7 no pre...

Page 24: ...na nella modalità RILEVAZIONE OSTACOLI Se il fine corsa di apertura non è installato E6 no e l apertura è in corso il sensore funziona nella modalità RILEVAZIONE OSTACOLI durante il tempo di lavoro normale A1 Durante il tempo di rallentamento A2 il sensore funziona nella modalità FINE CORSA Se il fine corsa di apertura non è installato E6 no e il tempo di rallentamento è disabilitato A2 00 il sens...

Page 25: ...ffetto Durante la chiusura Se le fotocellule esterne sono attivate la centrale blocca la chiusura e avvia l apertura L attivazione delle fotocellule interne non ha ha effetto F8 no LOGICA BATTENTE Durante l apertura Finché le fotocellule interne sono attivate la centrale sospende l apertura Quando le fotocellule vengono disattivate l apertura riprende L attivazione delle fotocellule esterne non ha...

Page 26: ...Se la memoria è piena i display visualizzeranno FF al momento del salvataggio r1 funzione di start La funzione di start avvia un ciclo di lavoro standard Il motore lavora per un tempo totale di A1 più A2 secondi durante l apertura e la chiusura r2 funzione di stop La funzione di stop ferma il cancello r3 funzione di pedonale La funzione di pedonale avvia un ciclo di lavoro pedonale il motore lavor...

Page 27: ...resso4 FotocellulaApertura E4 no DISABILITATO E4 tA ABILITATO L ingresso 4 è configurabile con queste funzioni Disabilitato no o Fotocellula Apertura tA La funzione Fotocellula Apertura è associata ad un contatto normalmente chiuso Durante la fase di installazione può essere utile disabilitare l ingresso 4 Quando le fotocellule sono collegate all ingresso 4 la centrale lo rileva e imposta E4 tA Fo...

Page 28: ...er avviare la procedura di acquisizione sequenziale Per passare al passo A1 premere un ingresso di start A1 Si sta acquisendo il Tempo Normale del motore A1 Il cancello si apre Per passare al passo di programmazione successivo Se il fine corsa d apertura non è installato E6 no Per passare al passo A2 premere un ingresso di start Se il fine corsa d apertura è installato E6 SI Per passare al passo A...

Page 29: ...ndo QK CE220RL4 è conforme ai requisiti essenziali di sicurezza delle direttive Apparecchiature Radio 1999 5 CE Bassa Tensione 2006 95 CE C 2004 108 CE macchina Sossano 10 11 2012 Via Seccalegno 19 36040 Sossano VI Italia Il Legale Rappresentante Luca Borinato ...

Page 30: ......

Page 31: ......

Page 32: ...facturer can technically improve the quality of its products without any prior notice Quiko Italy Via Seccalegno 19 36040 Sossano VI Italy Tel 39 0444 785513 Fax 39 0444 782371 info quiko biz www quikoitaly com ...

Reviews: