To restore the factory default setting, keep pressing button A or B until the display shows
d0
.
After a few seconds the control board shows
no
. To execute hold down button C until the
display shows
--
. The factory default has been set and the control board state is in stand by
state. This function doesn't have any effect on radio programming.
d0
Motor
Working Time
Programming
P1
is a semi-automatic procedure to acquire the working time parameters. The working time
parameters are
A1
,
A2
and
F0
. In other words, after this procedure the standard working
time, the slowdown working time of the motor and the pause time are acquired by the control
board. Before beginning this procedure, check that all safety devices are connected, the control
board is in stand by state, and the sense of rotation of the motor is correct. To begin this
procedure hold down or keep pressing button A or B until the control board display shows
P1
.
After a few seconds the control board display shows
__
.
After pressing a start input, the procedure will start. This procedure is divided into 3 steps:
A1
,
A2
and
F0
. In each step the linked parameter is programmed. During the whole programming
procedure the obstacle detection sensor is disabled.
P1
→
__
The control board is ready to start the motor working time programming.
To go to
A1
press any start input.
A1
The standard working time of the motor(
A1
) is being programmed.
The gate is opening. To change the programming phase:
If opening limit switch is not installed (
E6
=
no
):
•
To go to
A2
press any start input.
If opening limit switch is installed (
E6
=
SI
):
•
To go to
A2
press any start input.
•
To go to
F0
wait until the gate reaches the opening limit switch. An
extra time of 30 seconds will be added to
A1
.
A2
The slowdown working time of the motor (
A2
) is being programmed.
The gate is slowing down. To change the programming phase:
If opening limit switch is not installed (
E6
=
no
):
•
To go to
F0
press any start input.
If opening limit switch is installed (
E6
=
SI
):
•
To go to
F0
wait until the gate reaches the opening limit switch. An
extra time of 45 seconds will be added to
A2
.
F0
The pause time is being programmed (
F0
).
The gate is stopped. The flashing lamp is on. After a few seconds the control
board display shows the counting time. To finish the programming press any
start input and wait until the gate is completely closed.