BUTTONS
@
A
Scrolls menu from
A1
to
P2
@
B
Scrolls menu from
P2
to
A1
@
C
Increases value or set
SI
(
means: ON or ENABLED).
@
D
Decreases value or set
no
(
means: OFF or DISABLED).
Display Reports
St
Stop
FH
External pho
Internal photocell
tA
Internal photocell
mode 1
tC
External photocell
td
External photocell
mode 2
Go
Start
PE
Pedestrian start
oP
Open Only.
CL
Close Only.
Po
Dead man Open
PC
Dead man Close
EL
Electric-lock command
Eo
QK-SMARTM command
N.O.
A*
Motor A opening or
closing limit switch .
*B
Motor B opening or
closing limit switch.
Ab
Motor A and Motor B
opening or closing limit
switches.
+-
Remote key is pressed
5L
Assistance request from
cycle counter.
0t
Board damaged by
over-voltage.
1t
Photocells test error
7A
Motor A has detected
an obstacle
9A
Motor A is in thermal
protec on state
7b
Motor B has detected
an obstacle
9b
Motor B is in thermal
protec on state
FF
The radio memory is full
General Func ons
DISPLAY DEFAULT
@
C
MAX
@
D
MIN
DESCRIPTION
F0
10
sec
99
sec
00
sec
Automa c Closure Time.
To disable hold down
@
C
bu on un l display shows
5t
F1
07
sec
A1
sec
00
sec
Pedestrian me.
F2
0
sec
2.5
sec
0.0
sec
Kick back func on during
closing. It can be useful when an
electric-lock is installed.
F3
0.0
sec
4.0
sec
00
sec
Pre-blinking me
F4
NO
(OFF)
SI
(ON)
NO
(OFF)
Kick back func on during
opening.It can be useful when
an electric-lock is installed.
F5
NO
(OFF)
SI
(ON)
SI
(OFF)
Step-by-step func on
F6
NO
(OFF)
SI
(ON)
NO
(OFF)
Community mode
F8
SI
SI
NO
Photocells logic:
SI
→
Standard logic
no
→
Reverse logic
L0
NO
(OFF)
SI
(ON)
NO
(OFF)
Electric-lock
L1
00
00
min
10
min
Cold winter func on. This
func on is useful in countries
L3
no
SI
NO
Single Leaf Mode. Motor A
works only.
L5
no
E.9
A.1
L6
X
G.9
A.0
t1
NO
(OFF)
SI
(ON)
NO
(OFF)
Photocells test
t2
SI
(ON)
SI
(ON)
NO
(OFF)
Motors thermal protec on test
Radio Func ons
DISPLAY
@
C
DESCRIPTION
r0
1
...
2
...
Delete
To erase a remote control:
Hold down
@
C
bu on on the selected code un l the display
turns off
**
r1
=_
Save
To save a remote control key:
Hold down a
remote key. When the display shows
._
, push
down
@
C
bu on on the control board.
r1
→
Start
r2
→
Stop
r3
→
Pedestrian start
r4
→
r2
r3
r4
r5 no
Delete
To erase all codes
:Hold down
@
C
bu on
un l
display stops flashing
SI
r6
=_
Save
r7
r8
Terminal Block Se ngs
DISPLAY
@
C
@
D
DESCRIPTION
E1
↓
↑
no
= Disabled.
Go
=
Start N.O.
oP
= Open only N.O.
CL
= Close only N.O.
Po
= Dead man Open N.O.
PC
= Dead man Close N.O.
Eo
EL
= Electric lock command N.O.
E2
↓
↑
no
=
Disabled.
St
= Stop N.C.
A*
= Motor A opening and
closing limit switch N.O.
E3
↓
↑
no
=
Disabled.
tC
= External photocell N.C.
tD
= same like
tC
but with possibility to start
the opening even if external photocell is
detec ng an obstacle.
E4
↓
↑
no
=
Disabled.
tA
= Internal photocell N.C.
*B
= Motor B opening and
closing limit switch N.O.
E7
↓
↑
no
= Disabled.
PE
=
Pedestrian N.O.
oP
= Open only N.O.
CL
= Close only N.O.
Po
= Dead man Open N.O.
PC
= Dead man Close N.O.
Eo
EL
= Electric lock command N.O.
Motor B Se ng
DISPLAY DEFAULT
@
C
MAX
@
D
MIN
DESCRIPTION
B1
14
sec
99
sec
00
sec
Standard working me
b2
7
sec
99
sec
00
sec
Slowdown working me
b3
0.8
sec
1.5
sec
0.1
sec
Start up me (cue me)
b4
3
sec
99
sec
0
sec
Displacement me on opening
b5
6
10
1
Standard force
b6
8
10
1
Slowdown force
b7
NO
(DISABLED)
99 - NO
0
Standard obstacle detec on
threshold. During closing, for
standard working me, the
display shows motor B stress.
b8
NO
(DISABLED)
99 - NO
0
Slowdown obstacle detec on
threshold. During closing, for
slowdown working me, the
display shows motor B stress.
Motor A Se ng
DISPLAY DEFAULT
@
MAX
@
MIN
DESCRIPTION
A1
14
sec
99
sec
00
sec
Standard working me
A2
7
sec
99
sec
00
sec
Slowdown working me
A3
0.8
sec
1.5
sec
0.1
sec
Start up me (cue me)
A4
6
sec
99
sec
0
sec
Displacement me on closure
A5
6
10
1
Standard force
A6
8
10
1
Slowdown force
A7
NO
(DISABLED)
99 - NO
0
Standard obstacle detec on
threshold. During opening, for
standard working me, the
display shows motor A stress.
A8
NO
(DISABLED)
99 - NO
0
Slowdown obstacle detec on
threshold. During opening, for
slowdown working me, the
display shows motor A stress.
Courtesy Func ons
DISPLAY
DISPLAY
@
C
DESCRIPTION
d0
no
Set Up
To restore default se ng hold down
@
C
bu on un l display shows
--
P2
__
X
When a start command is received the
control board starts an automa c
procedure to acquire the gate working
mes.
IMPORTANT NOTICE:
when you see this symbol please refer
to the complete user manual for more
details. The complete user manual is
available for download in the reserved
area of our website.
quikoitaly.com
FUNCTION SUMMARY
QK-CE220BATRL4
QUICK GUIDE
CONTROL BOARD FOR 230V SWING GATES
MADE IN ITALY
®
MADE IN ITALY
®
Fast closure start
= QK-SMARTM command N.O.
= QK-SMARTM command N.O.
Programmable radio func ons. Save a remote
as one of following func ons: Only Open
oP
,
Only Close
CL
, open Dead Man
Po
,
close Dead Man
PC
, electric lock
EL
.
where the winter is
extremely cold.
Assistance request from
cycle counter.
Total working cycles
counter
V21 Hb2117
@
D
@
C
F7
5.0
sec
5.0
sec
1.5
sec
Fast closure delay