background image

BUTTONS

@

 A

Scrolls menu from 

A1

 to 

P2

@

 B

Scrolls menu from

 

P2

 to 

A1

@

 C

Increases value or set

 

SI

 

(

means: ON or ENABLED).

@

 D

Decreases value or set

 

no

 

(

means: OFF or DISABLED).

Display Reports

St

Stop

FH

External pho
Internal photocell

tA

Internal photocell 

mode 1

tC

External photocell 

td

External photocell 

mode 2 

Go

Start 

PE

Pedestrian start

oP

Open Only.

CL

Close Only.  

Po

 Dead man Open 

PC

Dead man Close

EL

Electric-lock command

Eo

QK-SMARTM command 
N.O.

A*

Motor A opening or 
closing limit switch .

*B

Motor B opening or 
closing limit switch.

Ab

Motor A and Motor B  
opening or closing limit 
switches. 

+-

Remote key is pressed

5L

Assistance request  from 
cycle counter. 

0t

Board damaged by 
over-voltage.

1t

Photocells test error

7A

Motor A has detected
an obstacle

9A

Motor A is in thermal 
protec on state

7b

Motor B has detected
an obstacle

9b

Motor B is in thermal 
protec on state

FF

The radio memory is full

General Func ons

DISPLAY  DEFAULT

@

 

C

MAX

@

 

D

MIN

DESCRIPTION

F0

10

sec

99

sec

00

sec

Automa c Closure Time.
To disable hold down 

@

 

bu on un l display shows 

5t

F1

07

sec

A1

sec

00

sec

Pedestrian  me. 

F2

0

sec

2.5
sec

0.0
sec

Kick back func on during 
closing. It can be useful when an
electric-lock is installed.

F3

0.0
sec

4.0
sec

00

sec

Pre-blinking  me

F4

NO

(OFF)

SI

(ON)

NO

(OFF)

Kick back func on during 
opening.It can be useful when 
an electric-lock is installed.

F5

NO

(OFF)

SI

(ON)

SI

(OFF)

Step-by-step func on

F6

NO

(OFF)

SI

(ON)

NO

(OFF)

Community mode 

F8

SI

SI

NO

Photocells logic:

SI

Standard logic

no

Reverse logic 

L0

NO

(OFF)

SI

(ON)

NO

(OFF)

Electric-lock

L1

00

00

min

10

min

Cold winter func on. This 
func on is useful in countries 

L3

no

SI

NO

Single Leaf Mode. Motor A 
works only.  

L5

no

E.9

A.1

L6

X

G.9

A.0

t1

NO

(OFF)

SI

(ON)

NO

(OFF)

Photocells test

t2

SI

(ON)

SI

(ON)

NO

(OFF)

Motors thermal protec on test

Radio Func ons

DISPLAY 

@

 

C

DESCRIPTION

r0

1

...

2

...

Delete

To erase a remote control: 

Hold down 

@

 

C

 

bu on on the selected code un l the display 
turns off 

**

r1

=_

Save

To save a remote control key:

 Hold down a 

remote key. When the display shows 

._

, push

down 

@

 

C

 bu on on the control board. 

r1

Start

r2

Stop

r3

Pedestrian start

r4

r2
r3
r4
r5 no

Delete

To erase all codes

:Hold down 

@

 

bu on

 

un l 

display stops flashing 

SI

r6

=_

Save

r7
r8

Terminal Block Se ngs

DISPLAY 

@

 

C

@

 

D

DESCRIPTION

E1

   

no

  = Disabled.

Go

  = 

Start N.O. 

 

oP

  = Open only N.O.

 

CL

  = Close only N.O.

Po

  = Dead man Open  N.O.

PC

  = Dead man Close N.O.

Eo

EL

  = Electric lock command N.O.

E2

   

no

  = 

Disabled.

St

  = Stop N.C.

A*

 = Motor A opening and 

            closing limit switch N.O.  

E3

   

no

  = 

Disabled.

tC

  = External photocell N.C. 

tD

  = same like 

tC

 but with possibility to start

              the opening even if external photocell is
              detec ng an obstacle. 

E4

   

no

  = 

Disabled.

tA

  = Internal photocell N.C.

*B

  = Motor B opening and  

             closing limit switch N.O. 

E7

   

no

   = Disabled.

PE

  = 

Pedestrian N.O.

 

oP

  = Open only N.O.

CL

  = Close only N.O.

Po

  = Dead man Open  N.O.

PC

  = Dead man Close N.O.

Eo

EL

  = Electric lock command N.O.

Motor B Se ng

DISPLAY  DEFAULT

@

 

C

MAX

@

 

D

MIN

DESCRIPTION

B1

14

sec

99

sec

00

sec

Standard working  me

b2

7

sec

99

sec

00

sec

Slowdown working  me

b3

0.8
sec

1.5
sec

0.1
sec

Start up  me (cue  me) 

b4

3

sec

99

sec

0

sec

Displacement  me on opening 

b5

6

10

1

Standard force

b6

8

10

1

Slowdown force

b7

NO

(DISABLED)

99 - NO

0

Standard obstacle detec on 
threshold. During closing, for 
standard working  me, the 
display shows motor B stress.

b8

NO

(DISABLED)

99 - NO

0

Slowdown obstacle detec on 
threshold. During closing, for 
slowdown working  me, the 
display shows motor B stress.

Motor A Se ng

DISPLAY  DEFAULT

@

 

MAX

@

 

MIN

DESCRIPTION

A1

14

sec

99

sec

00

sec

Standard working  me

A2

7

sec

99

sec

00

sec

Slowdown working  me

A3

0.8
sec

1.5
sec

0.1
sec

Start up  me (cue  me)

A4

6

sec

99

sec

0

sec

Displacement  me on closure 

A5

6

10

1

Standard force

A6

8

10

1

Slowdown force

A7

NO

(DISABLED)

99 - NO

0

Standard obstacle detec on 
threshold. During opening, for 
standard working  me, the 
display shows motor A stress.

A8

NO

(DISABLED)

99 - NO

0

Slowdown obstacle detec on 
threshold. During opening, for 
slowdown working  me, the 
display shows motor A stress.

Courtesy Func ons

DISPLAY 

DISPLAY

@

 

C

DESCRIPTION

d0

no

Set Up

To restore default se ng hold down 

@

 

C

 bu on un l display shows 

--

P2

__

X

When a start command is received the
control board starts an automa c 
procedure to acquire the gate working 

mes.

IMPORTANT NOTICE:

 

when you see this symbol please refer 
to the complete user manual for more 
details. The complete user manual is 
available for download in the reserved 
area of our website.

     quikoitaly.com

FUNCTION SUMMARY

QK-CE220BATRL4

QUICK GUIDE

CONTROL BOARD FOR 230V SWING GATES

MADE IN ITALY

®

MADE IN ITALY

®

Fast closure start

  = QK-SMARTM command N.O.

  = QK-SMARTM command N.O.

Programmable radio func ons. Save a remote 
as one of following func ons: Only Open 

oP

Only Close 

CL

, open Dead Man 

Po

,

close Dead Man 

PC

, electric lock 

EL

where the winter is 
extremely cold.  

Assistance request from 
cycle counter. 
Total working cycles 

counter 

V21 Hb2117

@

D

@

C

F7

5.0
sec

5.0
sec

1.5
sec

Fast closure delay

Summary of Contents for QK-CE220BATRL4

Page 1: ...20BATRL4 QUICK GUIDE CONTROL BOARD FOR 230V SWING GATES INPUTS OUTPUTS CONNECTION START N O E1 Go 2 3 4 1 8 9 10 1112 7 STOP N C E2 St 2 3 4 1 8 9 10 1112 7 E7 PE PEDESTRIAN N O 8 9 10 1112 7 230 VAC X 20 19 N L neutral phase 24 VDC OUTPUT FLASHING LAMP 24 VAC 20W 8 9 10 7 1112 24V 24V COM 400mA 8 9 10 7 1112 MOTOR A MA 14 15 13 MOTOR B MB 1718 16 13 open 14 common 15 close 16 open 17 common 18 cl...

Page 2: ...man Close N O Eo EL Electric lock command N O E2 no Disabled St Stop N C A Motor A opening and closing limit switch N O E3 no Disabled tC External photocell N C tD same like tC but with possibility to start the opening even if external photocell is detec ng an obstacle E4 no Disabled tA Internal photocell N C B Motor B opening and closing limit switch N O E7 no Disabled PE Pedestrian N O oP Open o...

Page 3: ...E COMMANDE POUR PORTAILS BATTANTS 230V PHOTOCELLULES INTERNES OUVERTURE PHOTOCELLULES EXTERNES FERMETURE BRANCHEMENTS DES PHOTOCELLULES PHOTOCELL EXT N C PHOTOCELL INT N C MODULE OPTIONNEL QK ELOCKM ÉLECTRO SERRURE 12V Vérifier que le contact ne soit pas relié RÉCEPTEUR PHOTOCELLULES BRANCHEMENT DES ENTRÉES SORTIES TRANSMETTEUR PHOTOCELLULES SANS TEST PHOTOCELLULES TRANSMETTEUR PHOTOCELLULES AVEC T...

Page 4: ...en l afficheur indique l effort du moteur A Seuil detec on obstacles en mode ralen Durant l ouverture pour un temps de travail ralen l afficheur indique l effort du moteur B Électro serrure Temps de fermeture rapide Temps mode pieton Pas à pas Mode copropriete Temps de pre clignotement Logique de photocellule SI Logique standard no Logique inverse Fonc on hiver froid Ce e fonc on est u le dans les pays ...

Reviews: