Installation.and.Maintenance
Service Manual
(1)
(2)
Terminal of
compressor
overload
protection
Terminal of
temperature
sensor
Terminal of
4-way valve
Terminal of
outdoor fan
Terminal of
compressor wire
PFC induction
wire
grounding wire
circlip
retainer
high and low
pressure switch
Remove the nut fixing axial flow blade and
then remove the blade.
Remove. the. grounding. wire. screw. on. the.
electric. box. assy. and. then. remove. the.
grounding.wire..(See.fig.1)
a
c
b
Disconnect. the. wiring. terminals. of. reactor,.
compressor,. high. and. low. pressure. switch,.
compressor.overload.protector,.temperature.
sensor,.outdoor.fan.motor.and.4-way.valve..(See.
fig.2)
N o t e : . k e e p . p r e s s i n g . t h e . c i r c l i p . w h e n.
disconnecting.the.wiring.terminal.of.reactor;.
keep.pressing.the.retainer.when.disconnecting.
other.wiring.terminals.
Remove.the.wire.inside.the.wiring.groove.
4..Remove.axial.flow.blade
axial.flow.blade
nut
5.Remove.electric.box.assy
Procedure
Step