23
Installation.and.Maintenance
Service Manual
9.2 Flashing LED of Indoor/Outdoor Unit and Primary Judgement
Note:
○
: off
●
: on
Ƽ
: blink
When several malfunctions occur at the same time, they will be displayed in circulation and every malfunction is
displayed for 5s.
NO Malfunction description
LED1
LED2
LED3
LED4
0
Normal stop
○
○
○
○
1
Compressor run
●
○
○
○
2
Compressor overload protection
Ƽ
○
○
○
3
Discharge protection
○
●
○
○
4
Outdoor unit overload protection
●
●
○
○
5
High pressure protection
Ƽ
●
○
○
6
Over current protection
○
Ƽ
○
○
7
IMP protection
●
Ƽ
○
○
8
IMP over heating protection
Ƽ
Ƽ
○
○
9
PFC protection (including PFC overheating protection)
○
○
●
○
10 Phase current protection
●
○
●
○
11 Over voltage protection
Ƽ
○
●
○
12 Insufficient voltage protection
○
●
●
○
13 Start failure
●
●
●
○
14 Compressor desynchronizing
Ƽ
●
●
○
15 Compressor phase-lacking protection
○
Ƽ
●
○
16 Compressor phase current detection malfunction
●
Ƽ
●
○
17 Memory chip mistake
Ƽ
Ƽ
●
○
18 DC power supply circuit-short
○
○
Ƽ
○
19 Defrosting
●
○
Ƽ
○
20 Oil return
Ƽ
○
Ƽ
○
21 Complete unit frequency restriction protection
○
●
Ƽ
○
22 Complete unit frequency dropping protection
●
●
Ƽ
○
23 Unit A frequency restriction or frequency dropping protection
Ƽ
●
Ƽ
○
24 Unit B frequency restriction or frequency dropping protection
○
Ƽ
Ƽ
○
25 Unit C frequency restriction or frequency dropping protection
●
Ƽ
Ƽ
○
26 Unit D frequency restriction or frequency dropping protection
Ƽ
Ƽ
Ƽ
○
27 Outdoor ambient temperature sensor protection
○
○
○
●
28 Outdoor tube temperature sensor protection
●
○
○
●
29 Discharge temperature sensor protection
Ƽ
○
○
●
30 IPM thermal resistance malfunction
○
●
○
●
31 Unit A liquid pipe temperature sensor malfunction
●
●
○
●
32 Unit A gas pipe temperature sensor malfunction
Ƽ
●
○
●
33 Unit B liquid pipe temperature sensor malfunction
○
Ƽ
○
●
34 Unit B gas pipe temperature sensor malfunction
●
Ƽ
○
●
35 Unit C liquid pipe temperature sensor malfunction
Ƽ
Ƽ
○
●
36 Unit C gas pipe temperature sensor malfunction
○
○
●
●
37 Unit D liquid pipe temperature sensor malfunction
●
○
●
●
38 Unit D gas pipe temperature sensor malfunction
Ƽ
○
●
●
39 Unit A mode conflict
○
●
●
●
40 Unit B mode conflict
●
●
●
●
41 Unit C mode conflict
Ƽ
●
●
●
42 Unit D mode conflict
○
Ƽ
●
●