5HPRYDO3URFHGXUH
b
a
b
c
O-Gasket sub-assy of Bearing
Cross Flow Blade
Fan Motor
Evaporator Assy
Motor Press Plate
Procedure
Steps
10. Remove axial flow blade and motor
Remove the screws between evaporator and
moor press plate, loosen the clasps fixing
evaporator and bottom case, and then remove
the evaporator.
Remove the screws connecting the motor press
plate and bottom case, and then remove the
motor press plate.
Take out the cross flow blade and motor,
remove the screws fixing the cross flow blade
and motor shaft, and then remove the motor.
Take out the shaft cushion block, remove the
screws of stepping motor, and then remove the
stepping motor.