Two Speed Wiring (for ES-3100, 4700, 5400, 6000, 7000, and STL PRO-3.3) 
(see Figure D)

1. 

Using a wire nut, connect the black wire from the power cord and the black wire 
from the fan to the black wire from the Hub. 

2. 

Connect the white wire from the power cord and the white wire on the fan to the 
white wire from the Hub. 

3. 

Connect the red wire from the fan to the red wire on the Hub 

4. 

Connect the blue wire from the fan to the blue wire on the Hub 

5. 

Cap the yellow wire from the Hub. 

6. 

Ground the green wire from the fan and the green wire from the power cord to 
the ground screw in the Hub. 

7. 

Set the dip switch positions inside the Hub as shown in the diagram below. 

8. 

Power-on the Hub. The Power LED indicator will be lit. 

9. 

Press the Test button to make sure the fan works. The Test LED indicator will 
blink twice every two seconds indicating 2-speed and the fan will be on high. 
Press the Test button again and the fan will switch to low speed. Press the Test 
button again and the fan should shut off and the LED will be off. 

10. 

If the fan doesn’t operate as described in step 9, please check the dip switch 
postion.

Attach green ground wires to ground screw

POWER           TIMER

PAIR

 TEST

Set dip switches: 

1 - OFF

2 - ON

3 - OFF

Power
Cord

All White Common Wires Together

Whole House Fan

ON

1 2 3

Attach green ground wires to ground screw

POWER           TIMER

PAIR

 TEST

Set dip switches: 

1 - OFF

2 - ON

3 - OFF

Power
Cord

All White Common Wires Together

Whole House Fan

ON

1 2 3

Figure D

Summary of Contents for IT-36002

Page 1: ...QUIETCOOLSYSTEMS COM 1 SEE HEAR FEEL THE QUIETCOOL DIFFERENCE ADVANCED WHOLE HOUSE FANS OWNER S GUIDE RF WIRELESS CONTROL...

Page 2: ...nly qualified service personnel should service the QuietCool system The user should not attempt to service the product CONTENTS 1 SYSTEM OVERVIEW 3 1 1 Introduction 3 1 2 Features 3 1 3 Key Specificat...

Page 3: ...ate the equipment 1 SYSTEM OVERVIEW 1 1 INTRODUCTION Congratulations on the purchase of your new QuietCool RF Wireless Control The QuietCool Whole House Fan RF Wireless Control is the simplest way to...

Page 4: ...torhead 4 Using your philips screwdriver open up the Hub and install the powercord bushing through the hole at the back of the hub 5 Run the motor wire leads through the large knockout in the bottom o...

Page 5: ...shown in the diagram below 7 Power on the Hub The Power LED indicator will be lit 8 Press the Test button to make sure the fan works The Test LED indicator will blink once every two seconds indicating...

Page 6: ...shown in the diagram below 8 Power on the Hub The Power LED indicator will be lit 9 Press the Test button to make sure the fan works The Test LED indicator will blink twice every two seconds indicati...

Page 7: ...Hub as shown in the diagram below 8 Power on the Hub The Power LED indicator will be lit 9 Press the Test button to make sure the fan works The Test LED indicator will blink twice every two seconds i...

Page 8: ...inside the Hub as shown in the diagram below 8 Power on the Hub The Power LED indicator will be lit 9 Press the Test button to make sure the fan works The Test LED indicator will blink twice every tw...

Page 9: ...diagram below 8 Power on the Hub The Power LED indicator will be lit 9 Press the Test button to make sure the fan works The Test LED indicator will blink three times every two seconds indicating 3 sp...

Page 10: ...l light up as shown below when the Test button is pressed and when the fan is turned on via the Wall Switch 1 One Speed Fan blink once every 2 seconds 2 Two Speed Fan blink twice every 2 seconds 3 Thr...

Page 11: ...cating successful pairing Press the Wall Switch button again the speed indicators will go out and it will display the current fan status 6 Press the Timer button to test the Wall Switch to make sure i...

Page 12: ...and screws mount the plate onto the drywall through the four mounting holes 3 OPERATION 3 1 Operating the Wall Switch Timer Button The top button on the switch controls the Timer functionality of the...

Page 13: ...ndicators are on and only one of the Speed LED indicators are on the fan is running in Continuous On mode at the indicated speed level The fan will continue to run until you press the Timer button to...

Page 14: ...e not in the correct position Disconnect power adjust your DIP switches and the only light that should be lit is your RED power light Why is there a medium speed if my fan is only a two speed The RF H...

Page 15: ...un install any components 3 Product failure or damage due to faulty installation abuse misuse unauthorized alteration to factory specs lack of maintenance or transportation damage 4 Shipping or postag...

Page 16: ...1 888 QUIETCOOL 16 ADVANCED WHOLE HOUSE FANS 43352 Business Park Drive Temecula CA 92590 PH 951 325 6340 QUIETCOOLSYSTEMS COM QuietCool is Proudly Designed and Built in California...

Reviews: