Page
75
of
86
If
a
patient
is
outside
the
normal
range
for
any
of
the
analytes,
then
the
result
will
be
flagged
by
reverse
video,
that
is,
the
background
of
the
result
will
be
black
and
the
value
in
white
numbers.
A
warning
will
be
displayed
below
the
results:
PATIENT
RESULT
ABNORMAL
If
the
Internal
QC
zones
for
the
device
or
a
specific
analyte
are
unacceptable,
the
analyte(s)
in
question
display
an
exclamation
point
(!)
in
place
of
a
value
and
a
warning
is
displayed:
!
INTERNAL
QC
OUT
OF
RANGE
.
If
the
QC
Sample
for
a
specific
analyte
on
that
device
lot
is
unacceptable,
the
analyte
in
question
will
display
a
pound
sign
(#)in
place
of
a
value
and
a
warning
is
displayed:
#
QC
SAMPLE
OUT
OF
RANGE
.
If
both
QC
Sample
and
Internal
QC
errors
are
present
for
a
specific
analyte,
both
a
pound
sign
and
an
exclamation
point
(#
!)
will
be
displayed
in
place
of
a
value
and
both
warnings
are
displayed:
!
INTERNAL
QC
OUT
OF
RANGE
and
#
QC
SAMPLE
OUT
OF
RANGE
.
3.
Blocked
Results
When
QC
error
conditions
exist
on
a
test
device,
whether
for
a
specific
analyte
or
the
entire
test
panel,
the
analytes
in
question
are
blocked
from
view
and
replaced
with
an
Out
of
Range
Flag
(!
and/or
#).
The
error
condition
must
be
remedied
and
the
test
repeated
to
obtain
a
result.
4.
QC
Sample
Frequency
How
often
an
external
liquid
control,
QC
Sample,
should
be
run
can
be
selected
under
SET
PARAMETERS
.
If
the
time
interval
has
expired,
QC
Samples
must
be
run
and
acceptable
results
obtained
before
a
patient
sample
can
be
tested.
A
list
of
test
device
lots
and
the
date
that
the
QC
Sample
expires
can
be
viewed
and
printed
by
selecting
REAGENT
LOTS
–
QC
under
the
RECALL
RESULTS
menu.
5.
Supervisor
Access
To
prevent
misuse,
the
Supervisor
CODE
CHIP
module
is
required
for
access
to
the
SET
PARAMETERS
and
DELETE
RESULTS
functions
of
the
software.
The
Supervisor
CODE
CHIP
is
universal
and
may
be
used
on
any
Quidel
Triage
MeterPro.
Limited
Warranty.
FOR
THE
APPLICABLE
WARRANTY
PERIOD,
QUIDEL
WARRANTS
THAT
EACH
PRODUCT
SHALL
BE
(I)
OF
GOOD
QUALITY
AND
FREE
OF
MATERIAL
DEFECTS,
(II)
FUNCTION
IN
ACCORDANCE
WITH
THE
MATERIAL
SPECIFICATIONS
REFERENCED
IN
THE
PRODUCT
MANUAL,
AND
(III)
APPROVED
BY
THE
PROPER
GOVERNMENTAL
AGENCIES
REQUIRED
FOR
THE
SALE
OF
PRODUCTS
FOR
THEIR
INTENDED
USE
(the
“LIMITED
WARRANTY”).
IF
THE
PRODUCT
FAILS
TO
MEET
THE
REQUIREMENTS
OF
THE
LIMITED
WARRANTY,
THEN
AS
CUSTOMER’S
SOLE
REMEDY,
QUIDEL
SHALL
EITHER
REPAIR
OR
REPLACE,
AT
QUIDEL'S
DISCRETION,
THE
PRODUCT.
EXCEPT
FOR
THE
LIMITED
WARRANTY
STATED
IN
THIS
SECTION,
QUIDEL
DISCLAIMS
ANY
AND
ALL
WARRANTIES,
EXPRESS
OR
IMPLIED,
INCLUDING
BUT
NOT
LIMITED
TO,
ANY
WARRANTY
OF
MERCHANTABILITY,
FITNESS
FOR
A
PARTICULAR
PURPOSE
AND
NON
Ͳ
INFRINGEMENT
REGARDING
THE
PRODUCT.
QUIDEL'S
MAXIMUM
LIABILITY
WITH
ANY
CUSTOMER
CLAIM
SHALL
NOT
EXCEED
THE
NET
PRODUCT
PRICE
PAID
BY
CUSTOMER.
NEITHER
PARTY
SHALL
BE
LIABLE
TO
THE
OTHER
PARTY
FOR
SPECIAL,
INCIDENTAL
OR
CONSEQUENTIAL
DAMAGES,
INCLUDING,
WITHOUT
LIMITATION,
LOSS
OF
BUSINESS,
PROFITS,
DATA
OR
REVENUE,
EVEN
IF
A
PARTY
RECEIVES
NOTICE
IN
ADVANCE
THAT
THESE
KINDS
OF
DAMAGES
MIGHT
RESULT.
The
Limited
Warranty
above
shall
not
apply
if
the
Customer
has
subjected
the
Product
to
physical
abuse,
misuse,
abnormal
use,
use
inconsistent
with
the
Product
Manual
or
Insert,
fraud,
tampering,
unusual
physical
stress,
negligence
or
accidents.
Any
warranty
claim
by
Customer
pursuant
to
the
Limited
Warranty
shall
be
made
in
writing
within
the
applicable
Limited
Warranty
period.
Summary of Contents for Triage MeterPro
Page 1: ...Page 1 of 86 User Manual...
Page 13: ...Page 13 of 86 Parts of the Quidel Triage MeterPro...
Page 83: ...Page 83 of 86...
Page 84: ...Page 84 of 86...
Page 85: ...Page 85 of 86...