IndIcators

7.11 charging and programming socket:

(Fig.9.10)

warnIng!

This socket should only be used for programming and 

• 

charging the wheelchair. 

This socket should not be used as a power supply for 

• 

any other device. 

Connection  of  other  electrical  devices  may  damage 

• 

the control system or affect the EMC performance of 

the wheelchair.

See Section 9.0 about charging.

The programming socket will enable an approved Sunrise 

Medical  authorised  dealer  to  re-programme  your  chair 

and also gain useful information when tracing any faults. 

When the chair leaves the factory, the parameters of the 

controller are set to default.

To  programme  the  controller  you  need  a  special 

programming device (handheld or PC software), which is 

available to your Sunrise Medical authorised dealer.

warnIng!

 

 

Programming  the  controller  of  the  wheelchair  is  only 

allowed through authorised personnel trained by Sunrise 

Medical. Incorrect controller settings could cause driving 

outside  the  safe  limits  and  could  result  in  damage  or 

injury.

note:

  Sunrise  Medical  does  not  accept  responsibility 

for  damages  which  result  from  unexpected  movement 

or  stopping  of  the  wheelchair  due  to  inappropriate 

programming or unauthorised use of the wheelchair.

7.12 vr2 dual control unit:

7.13 control button and indicator:

This shows which joystick has control. If the red wheelchair 

light is on the wheelchair occupants joystick has control. If 

the green attendant light is on the dual attendant systems 

joystick has control. The button is used to transfer control 

between the two choices, (Fig.7.4).

7.14 actuator button and led:

All VR2 dual attendant systems have an actuator button 

fitted  as  standard.  If  the  VR2  is  programmed  with  no 

actuators then this button has no function, (Fig.7.4).

wheelchairs with one actuator:

Depressing  the  actuator  button  once  will  enter  actuator 

adjustment mode. This will be indicated by the illumination 

of both actuator LED’s. Actuator adjustment can then be 

made by deflecting the joystick forwards and backwards.

To re-enter drive mode, depress either the actuator button 

or the speed button.

wheelchairs with two actuators:

Depressing  the  actuator  button  will  enter  actuator 

adjustment mode. Depressing the button once illuminates 

the  left  LED  and  deflection  of  the  joystick  forwards  or 

backwards  will  adjust  the  actuator  connected  to  that 

channel. Selection between the two actuators is achieved 

by deflecting the joystick to the left and right. As the actuator 

selected changes so will the LED which illuminates. Left 

for actuator 1 and right for actuator 2.

To re enter drive mode, depress either the actuator button 

or the speed button.

Control panel

Joystick

VR2 Dual Control Unit

fig. 7.3

Control 

button & 

Indicator 

LED’s

Actuator 

button

Speed 

indicator

Maximum 

speed button

fig. 7.4

VR2 Dual Control Unit

Summary of Contents for Tango

Page 1: ...Instructions for Use Quickie Tango Powered Wheelchair 034202 UK...

Page 2: ...al com or alternatively is available on request in large text For further information on the full specification and options and accessories please refer to the order form All information is subject to...

Page 3: ...it can be used by those who cannot walk or have limited mobility e g because of Paralysis Loss of extremity leg amputation Extremity defect deformity Joint contractures joint injuries Strokes and brai...

Page 4: ...e of adjustments the Quickie Tango is a perfect choice for easy service refurbishment and recycle requirements As a part of our ongoing product improvement initiative Sunrise Medical reserves the righ...

Page 5: ...0 12 3 Medium to long term storage 40 13 0 Disposal 41 14 0 Specifications 41 15 0 Guarantee 42 16 0 Service History 42 17 0 Performance checks 43 1 0 Your Wheelchair 7 2 0 How to use this manual 7 2...

Page 6: ......

Page 7: ...Sunrise Business Park High Street Wollaston West Midlands DY8 4PS England Phone 44 0 1384 44 66 88 Fax 44 0 1384 44 66 99 2 0 How to use this manual 2 1 Introduction Please keep a note of your local...

Page 8: ...rect result of a The wheelchair or part not having been maintained or serviced in accordance with the manufacturer s recommendations as stated in the Owner s Manual and or Service Manual Or failing to...

Page 9: ...and for conformance to strict standard requirements Changing the fitted position of the module can reduce the stability of the product therefore do not change this setting Battery Label Warning Instr...

Page 10: ...l For further information please consult your Sunrise Medical authorised dealer DANGER 4 3 Preliminary checks You should not try to manoeuvre at full speed If you have to make a sudden turn slow down...

Page 11: ...sition and secured by the wheelchair tie down and occupant restraint straps WTORS tie downs meeting the requirements of ISO 10542 or SAE J2249 in accordance with the WTORS manufacturers instructions F...

Page 12: ...ig 4 4 The upper torso restraint belt should be mounted to the vehicle B pillar failure to do so will increase the risk of serious abdominal injuries to the user DANGER A head restraint suitable for t...

Page 13: ...consistent with user comfort Restraint belt webbing must not be twisted when in use Restraints should be mounted to the vehicle B pillar and should not be held away from the body by wheelchair compon...

Page 14: ...turned off The operation of cordless mobile telephones and cell phones including hands free devices is permitted but if abnormal operation of the wheelchair is encountered then the chair must be brou...

Page 15: ...possible there may be other traffic WARNING 4 16 Adverse conditions Please be aware that when driving your wheelchair in adverse conditions e g on wet grass mud ice snow or other slippery surfaces you...

Page 16: ...ou should start slowly On a RWD chair if necessary lean forward to prevent the tendency for the front wheels to lift WARNING 4 22 Gradients descents On descents it is important not to let the wheelcha...

Page 17: ...t an angle of approximately 45 and when correctly adjusted should not allow user to slip down in the seat Fig 4 18 To fasten buckle Firmly push the male buckle into female buckle Fig 4 19 To release b...

Page 18: ...n ask your healthcare professional wheelchair dealer carer or attendant for assistance WARNINGS The rider plus item should never exceed a total weight of 125 kg Before you use the chair carefully chec...

Page 19: ...5 0 Fig 5 1 5 3 Anti tip wheels Fig 5 3 These are mounted when the wheelchair leaves the factory The anti tip wheel tube is welded to the motor retaining plate of the wheelchair frame Note Anti tips...

Page 20: ...proceed as follows WARNING All wheels are safety critical items If you are unsure about performing these tasks please contact your approved Sunrise Medical dealer Front castor wheel Fig 5 6 Use a 6 mm...

Page 21: ...interfering with the mechanisms of the chair Ensure that the crutch does not protrude from the chair Do not attempt to remove the crutch whilst the chair is in motion Always come to a complete stop a...

Page 22: ...back 3 to 12 Fig 6 1 The backrest can be adjusted in 3 increments by removing the two star knobs To reposition choose the required back angle insert the two star knobs again and tighten 6 4 Manual Rec...

Page 23: ...Direct Actuator Control CAUTION Operating the powered tilt greater than 9 degrees from its lowest position will bring the chair into creep mode allowing slow speed driving only To operate the powered...

Page 24: ...If your chair has a powered seat tilt powered recline or manual recline back we strongly recommend that you bring the backrest into an upright position and set the seat tilt to the level position If...

Page 25: ...rb climber or castor makes contact with the kerb step the wheelchair should be moving slowly Small kerbs can be climbed from a standstill Apply sufficient power to the motors to lift the front of the...

Page 26: ...low To lock the wheelchair While the control system is switched on depress and hold the On Off button After 1 second the control system will beep Now release the On Off button Deflect the joystick for...

Page 27: ...indicates if the speed of the wheelchair is being limited or if the control system is locked 7 6 The horn button The horn will sound while this button is depressed 7 7 Speed Profile decrease button Th...

Page 28: ...perate this button the associated LED will flash at the same rate The left and right turn indicator LEDs will also flash If the LED flashes rapidly either a total short circuit a single lamp open circ...

Page 29: ...ich joystick has control If the red wheelchair light is on the wheelchair occupants joystick has control If the green attendant light is on the dual attendant systems joystick has control The button i...

Page 30: ...profile s needs adjustments to make it more convenient for the attendant and or the person sitting in the wheelchair please contact your Sunrise Service agent for adaptation If the direction of moveme...

Page 31: ...can t find the problem try the self help guide on the next page Switch on the control system again and try to drive the wheelchair If the safety circuits operate again switch off and do not try to us...

Page 32: ...r has a bad connection Check the connections to the left hand motor The left hand motor has a short circuit to a battery connection Contact your Sunrise Medical authorised dealer The right hand motor...

Page 33: ...sed dealer as soon as possible who will carry out a full diagnostic to determine the cause of the original the fault WARNING Do not attempt to change the fuses yourself Do not attempt to by pass the f...

Page 34: ...34 Quickie Tango Fig 9 2 Fig 9 4 Fig 9 6 Fig 9 8 Fig 9 3 Fig 9 5 Fig 9 7 Fig 9 9 Side clips Inner clips...

Page 35: ...llowed this may result in lower than expected performance from your mobility vehicle 9 7 Maintenance free battery care plan Only use an approved Sunrise Medical charger compatible with the vehicle to...

Page 36: ...ith the same type and size of fuse as specified Fitting of different fuses can result in damage to the charger or failure of the charger to operate properly If your charger has been specified for use...

Page 37: ...ature is very hot or very cold Incorrect tyre pressures in one or more tyres Lots of start stop driving Also thick pile carpets within the home can affect range Use of additional power consumption opt...

Page 38: ...y forwards 45mm Armrest retainer forward biased and armpad fixed in the fully backwards position 47 5mm Armrest retainer rearward biased and armpad fixed fully forwards 50mm Armrest retainer rearward...

Page 39: ...wanted movement of your wheelchair Keep your fingers and clothing etc clear while operating the swing away mechanism Be aware that the width of your chair has increased if the swing away arm is out an...

Page 40: ...nts The wheelchair may be transported by road rail sea or air and the batteries conform to IATA regulations CAUTION Before you travel please contact the appropriate carrier The travel operator will be...

Page 41: ...ovable part Static stability downhill 20 3 tilt 3 recline Static stability uphill 14 3 tilt 3 recline Static stability sideways 18 3 tilt 3 recline Energy consumption max range 25km 6kph motor 100kg u...

Page 42: ...exceeded if the product is carefully used and properly maintained The life expectancy can also be considerably reduced by extreme or incorrect usage The fact that we estimate a life expectancy for thi...

Page 43: ...al for inside use low seat height compact dimensions as well as outside use lights 40Ah 50Ah batteries etc Its high level of flexibility due to the number of possible adjustments and the modular platf...

Page 44: ...unrisemedical com Sunrise Medical Srl Via Riva 20 Montale 29100 Piacenza PC Italy Tel 39 0523 573111 Fax 39 0523 570060 www sunrisemedical com Sunrise Medical A G L ckhalde 14 3074 Muri bei Bern Switz...

Reviews: