background image

 

 

Buzzer symbol 

 

Shows the hot air volume. 

 

Shows  the  temperature  timing,  it  is  preset  timing 
down to 0. 

 

Shows temperature unit (

/

 

Shows the heating element is heating. 

 

Show the heating element preset temperature value. 

 

Shows the heating element is cooling. 

 

Shows lock or unlock status. 

10 

 

Display real time temperature value. 

 

Press and hold “2” button to enter into channel set menu, you can press “+” or “-” button to 

select channel, , see following picture, there are nine channels can be set.   

BACK

SET

SLEEP

CH1

2
3

4

5
6

245

240

320

350

380

Cool

40L/M
60L/M
60L/M
60L/M

50L/M
70L/M

50S
40S
50S
50S

50S
50S

 

Press “3” button to activate the parameters (blue indicates it is activated), press “+” or “-” 

button to set the number of channel and press “2” button to save.   

NOTE: There are six steps in every channel, and the first five steps are heating status, 

the last one is cooling status! 

Summary of Contents for TR1350

Page 1: ...TR1350 Rework System Instruction Manual Thank you for purchasing our production Keep this manual handy for future reference...

Page 2: ...2 Dimension 5 7 Operation Process 6 7 1 Turn ON OFF 6 7 2 Foot Switch Function 6 7 3 Sleep and Work Mode 6 7 4 Break Sleep Method 7 8 Menu Setting 7 8 1 Main Menu 7 8 2 Data Set Menu 9 8 3 System Set...

Page 3: ...them with your hands to avoid burns Notify other personnel of the factory that this system is extremely susceptible to burn and may cause dangerous accidents Turn off the system when resting or after...

Page 4: ...rates temperature control and air volume control Use ten channels to control air volume temperature and time ect Digital temperature calibration easy to use Equip with the DC brushless motor Light han...

Page 5: ...ctions of all buttons In Set menu press button once to increase the gun temperature value by one digit press and hold it to continuously increase In Set menu press button once to decrease the gun temp...

Page 6: ...r connecting or disconnecting rework system 2 Power inlet module connect the outlet of the power supply 220V AC power line into power inlet module 3 ESD socket 4 RJ11 socket it follows RS485 Standard...

Page 7: ...foot switch to enter into cool process when the machine is working During sleep mode press foot switch to enter into working process 2 The foot switch is invalid when the hot air gun is placed in the...

Page 8: ...the sleep is break when you press 1 button 3 Press the foot switch to break sleep 4 Sent break sleep code when the equipment is communicated with other machine 8 Menu Setting 8 1 Main Menu Function o...

Page 9: ...ess and hold 2 button to enter into channel set menu you can press or button to select channel see following picture there are nine channels can be set BACK SET SLEEP CH1 2 3 4 5 6 245 240 320 350 380...

Page 10: ...cture 2 Press 1 button to move the cursor to the required item such as Data Set and press 3 button to enter into Data Set Menu see following picture 3 You can press or button to select the required ch...

Page 11: ...Password 3 Press or button to select the number and press 1 to change digit The default password is 000000 4 Enter the new password two times it is changed successfully after the same new password is...

Page 12: ...temperature mode ON OFF 4 Press or button to change temperature value the preset value is 2 99 5 Press 3 button to save 6 Press 2 button to back 8 3 4 ESD Test 1 Press or button to move the cursor to...

Page 13: ...2 Press 3 button to activate Address 3 Enter the password 4 Enter required address 5 Press or button to select number and press 1 button to change digit 6 Press 3 button to save 7 Press 2 button to ba...

Page 14: ...displayed when there is something wrong with the equipment NO Handle handle is not inserted Sensor Error temperature sensor error Room Sensor Error temperature offset sensor error Heater Error heating...

Page 15: ...QUICK INTELLIGENT EQUIPMENT CO LTD ADD NO 11 FengXiang Road Wujin High Tech Industrial Development Zone Jiangsu China TEL 86 519 86225678 FAX 86 519 86558599 POSTCODE 213167 WEBSITE www quick global c...