(1)
With supply voltage less than 8 Vdc the remote control can reset.
(2)
Typical value with remote control disabled.
(3)
Typical value with remote control enabled.
(4)
Excluding the back of the remote control (IP20).
TECHNICAL DATA
MAINTENANCE
The TCD 1062 needs no particular maintenance.
To ensure optimum performance from the TCD 1062, once a year check the cables and the electrical connections.
Clean the TCD 1062 with a soft cloth dampened with water.
Do not use chemical or abrasive products to clean the TCD 1062.
MODEL
TCD 1062
MAIN SWITCH COMMAND CHARACTERISTICS
Supply voltage (1)
from 8 to 31 Vdc
Quiescent current (2)
10 mA
Maximum current absorption (3)
40 mA
THRUSTER COMMAND CHARACTERISTICS
Current capacity of right or left
single thruster commands.
4 A
Supply voltage (1)
from 8 to 31 Vdc
Quiescent current (2)
10 mA
Maximum current absorption
(3)
95 mA + absorption of the contactor coil
GENERAL
Operating temperature
from -20 to +70 °C
Protection rating
(4)
IP 65
EMC Standard
EN 60945 - FCC PART 15 RULES 47
Weight
110 g
Dimensions including frame (L x L)