To distinguish whether the signal concerns the bow or the stern of the boat they will be steadily lit, simultaneou-
sly with the fl ashing of the enablement LEDs, the green LED and the red LED of the involved part (bow or stern).
The resetting of this class of problems occurs, once the cause that has generated them has been removed, by
switching off and switching back on the remote control.
When problems 3, 4, 5 are present, it may be necessary to turn off and turn back on the external devices that
signalled the problem. Refer to their installation and use manual.
QUICK
®
RESERVES THE RIGHT TO MODIFY THE TECHNICAL CHARACTERISTICS OF THE EQUIPMENT AND THE CONTENTS OF THIS MANUAL WITHOUT PRIOR NOTICE.
(1)
With supply voltage less than 8 Vdc the remote control can reset.
(2)
Typical value with remote control disabled.
(3)
Typical value with remote control enabled and both joysticks activated.
(4)
Excluding the back of the remote control (IP20).
TECHNICAL DATA
MAINTENANCE
The remote control needs no particular maintenance. To ensure optimum performance from the remote control,
once a year check the cables and the electrical connections.
Clean the remote control with a soft cloth dampened with water. Do not use chemical or abrasive products to
clean the remote control.
MODEL
TCD 1044
OUTPUT CHARACTERISTICS
Current capacity of right or left single thruster
commands.
4A max
INPUT CHARACTERISTICS
Supply voltage
(1)
from 8 to 31 Vdc
Current absorption
(2)
10 mA
Maximum current absorption
(3)
95 mA + absorption of the contactor coil
AMBIENT CHARACTERISTICS
Operating temperature
from -20 to +70 °C
Protection rating
(4)
IP 66
GENERAL
Dimensions including frame (L x L)
78 mm x 131 mm
Weight
250 g
EMC class
EN 60945 - FCC Part 15 Rules 47
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: