15
EN
BOILER B3 15/20 12V - REV001A
WARNING:
if the high temperature safety system
switches on repeatedly, call Quick
®
service center.
MAINTENANCE
During wintertime, when the water heater is not in
use it should be drained using the lever of the valve
(4). This is to avoid serious damage caused by freez-
ing.
The overpressure release device must be activated regular-
ly to remove calcium deposits and to ensure that it is not
blocked.
Periodically check the joints of the water pipe installation;
check the tightness of the securing screws and replace them
in case they are worn or corroded.
Also periodically check the electrical system working order.
F
POS. DESCRIPTION
1
RED PLASTIC WASHER
2
WHITE PLASTIC WASHER
3
BLUE PLASTIC WASHER
4
RELIEF/NON RETURN VALVE
5
HOSE CLAMP
6
DISCHARGE PIPE
7
ELEMENT GASKET
FROM S/N 100.000
8
ELECTRIC ELEMENT 12V
9
B3 RESISTOR COVER 12V
10
SCREW
11
B3 TANK MOUNTING 300
12
B3 METAL BRACKET 300
13
SCREW
14
WASHER
15
NUT
16
CABLE CLAMP
17
SCREW
MAINTENANCE
Summary of Contents for B3 12V Series
Page 2: ......
Page 8: ...8 BOILER B3 15 20 12V REV001A IT MANUTENZIONE 1 2 2 9 3 12 15 14 13 11 4 16 17 6 10 8 7 A 5...
Page 14: ...14 EN BOILER B3 15 20 12V REV001A 1 2 2 9 3 12 15 14 13 11 4 16 17 6 10 8 7 A 5 MAINTENANCE...
Page 20: ...20 FR BOILER B3 15 20 12V REV001A 1 2 2 9 3 12 15 14 13 11 4 16 17 6 10 8 7 A 5 ENTRETIEN...
Page 26: ...26 DE BOILER B3 15 20 12V REV001A 1 2 2 9 3 12 15 14 13 11 4 16 17 6 10 8 7 A 5 WARTUNG...
Page 32: ...32 ES BOILER B3 15 20 12V REV001A 1 2 2 9 3 12 15 14 13 11 4 16 17 6 10 8 7 A 5 MANTENIMIENTO...
Page 38: ...38 PT BOILER B3 15 20 12V REV001A 1 2 2 9 3 12 15 14 13 11 4 16 17 6 10 8 7 A 5 MANUTEN O...
Page 50: ...50 NL BOILER B3 15 20 12V REV001A 1 2 2 9 3 12 15 14 13 11 4 16 17 6 10 8 7 A 5 ONDERHOUD...