参数键

 

Parameter 

按此键进入参数,参数调好后按此键保存并退出参数模式

 

Pressing this key enters parameters, after adjusting 

parameters presses this key to save. 

 

 

 

确认保存键

 

Save 

按此键确认调整后的参数

 

Pressing this key confirms adjusted 

parameters 

 

 

 

补针按钮

 

One Stitch 

每按一次补一针

 

One stitch plus pressing once. 

 

4.

一级参数菜单(机修工菜单)

Parameter Manual (Technician Manual) 

参数号

 

No. 

参数名称

 

Explaination 

of Parameter 

出厂设置

 

Setting 

用户可

 

调整范围

 

Setting Scope 

具体说明

 

Description 

P-01 

最高缝纫速度

 

Max. Speed 

3700 rpm 

500-4000rpm 

 

 

P-02 

起步限速设置

 

Starting Speed 

Limit Set 

200rpm 

150-800rpm 

 

 

P-03 

慢速起缝设置

 

Soft Start Set 

0/1 

0:

慢速起缝关闭;

 

0: Disable Soft start 

1:

慢速起缝开启

1: Enable soft start 

P-04 

恢复出厂设置

 

Factory Reset 

0/1 

1: 

恢复出厂参数

 

1

Reset the factory code. 

 

功能调整范例:(

Example

 

恢复出厂设置功能:

1.

P

键,控制面板显示

P-01

2.

按加速键或减速键,可调整到需要的参数号,例如

P-04

3.

S

键,进入恢复出厂设置功能,面板显示默认值

0

4.

按加速键或减速键,可修改参数内容为

1

5.

S

键保存,提示

ok

,回到显示

P-04

6.

P

键退出,进入正常使用环境。

 

Factory Reset Function:

 1.Press P, panel displays P-01; 2.Press Accelerator or Decelerator Key, adjust 

the paremeter number to P-04 for example; 3. Press S, enter into the Factory Reset function, panel 

displays the default value as 0; 4.Press Accelerator or Decelerator Key, adjust the paremeter value to 1; 

5.Press S to save the new value, display ok and back to P-04; 6. Press P to return to the general using 

mode. 

 

5.

故障提示

 Trouble Display 

故障代码

 

Error Code 

故障名称

 

Error Meaning 

解决方案

 

Solution 

Summary of Contents for 8801

Page 1: ...or dew and mist of places 4 Install the control box and other components turn off the power and unplug the power cord 5 To prevent interference or leakage accidents please do the ground work the power...

Page 2: ...wn onto the back side of machine and tighten up 4 screws with 3mm hexagonal socket 3 Install the controller box Put motor power cable and motor hall cable into controller plug then install the control...

Page 3: ...ation and disassembly of any electronic control elements must switch off the machine All power cord signal lines ground lines wiring not to be pressed into other objects or excessive distortion to ens...

Page 4: ...y slow down pressing one time 100rpm 2 After entering parameters mode adjusting parameters downward 3 Needle Position 1 y dn y up 2 T on T of LG03 LG04 1 Pressing this key changes needle position up a...

Page 5: ...1 0 0 Disable Soft start 1 1 Enable soft start P 04 Factory Reset 0 0 1 1 1 Reset the factory code Example 1 P P 01 2 P 04 3 S 0 4 1 5 S ok P 04 6 P Factory Reset Function 1 Press P panel displays P...

Page 6: ...please check the head is stuck or not sewing materials is too heavy or not the machine lack oil or not Then check the Hall electric machine is good or not If every thing is good please contact with d...

Page 7: ...is deformation or not Non professionals to ban open controller housing to avoid the electric shock Er 7 Adjust Foot Speed Signal Abnormality If machine have this problem it is mean motor foot switch h...

Page 8: ......

Reviews: