USER MANUAL
9
After setting a new password in the initial state, it must turn off the power switch and
then turn on it, and then the locking function of the parameter setting comes to run. Or
else, it can change the parameter after changing the password.
2.7.
Error Messages
1.
Heater error: If there is some malfunction in the heater or in the heater
circuit, the temperature parameter of LCD will display “H-E”. It must test
the heater and the correlative parts.
2.
Sensor error: If there is some malfunction in the sensor or in the sensor
circuit, the temperature parameter of LCD will display “S-E” and the power
supply to the handle will be cut off.
3.
ERR: If there is some malfunction in the fan or in the fan circuit, the LCD will
display “ERR” and it must test the fan and the correlative parts.
2.8.
Sleeping
2.8.1. How into the Sleeping State
1.
Put the handle on the handle holder, the system will to the sleeping
state come automatically.
2.
During the system from work state to sleeping state, the window will
display “Off”. and then when the temperature cooling down to 100
℃
,
the unit comes into the sleeping state. In the sleeping state, the LCD
will display “Sleep”.
2.8.2. Resume
1.
When the handle is putting on the handle, it cannot be resumed from
sleeping.
2.
Take down the handle from the holder. At the time, the unit will work at
once.