MANUAL DE USUARIO

8

2. Installation

Open the box carefully so as not to damage any parts, and make sure the contents are as follows:

Installation

Template

Temperature Kit

(sold separately)

Pass-through kit  

(sold separately)

QUICKSALT

control unit

Housing and 

Electrolytic cell

Water flow sensor

(flow switch)

Racord and 

mounting clamps

Unless you are sure that the PVC pipes do not contain water when you cut and/

or drill them. Use a battery-powered drill and not one that requires connection 

to the mains.

2.1. Tools

Below you will find the necessary tools for the electrical and hydraulic installation of your 

QUICKSALT 

equipment:

- Cleaner and glue for PVC pipes
- Cutting saw suitable for PVC
- Allen key set.
- Set of screwdrivers and tools needed for electrical connection to the control and protection   

  panel of the pump.

Summary of Contents for QUICKSALT20

Page 1: ...MANUAL DE USUARIO 1 USER S GUIDE 20 40 60...

Page 2: ...ion services or part replecement Please have your model and serial numbers available for your supplier The part list can be found on page 24 of this manual MODEL REF VOLTAGE SERIAL NUMBER POOL VOLUME...

Page 3: ...jury and even death Throughout the manual you will find two types of information to which you should pay particular attention DANGER Risk of electric shock explosion or any other risk that endangers p...

Page 4: ...MANUAL DE USUARIO 4...

Page 5: ...ting options 09 2 3 Hydraulic installation 10 2 4 Electrical Installation 15 2 4 1 Connection to the switchboard 15 3 Starting up 16 3 1 Preparation of the pool water 16 4 Operation 18 4 1 Maximum pro...

Page 6: ...this equipment Do not use the equipment if you notice that any of the cables power supply or cell are damaged Disconnect it immediately and contact your service representative if this happens Make sur...

Page 7: ...tion can be adjusted via the control interface In addition the equipment will notify you of any incident that may occur by means of an audible alarm indicating the reason on the screen and stopping it...

Page 8: ...cord and mounting clamps Unless you are sure that the PVC pipes do not contain water when you cut and or drill them Use a battery powered drill and not one that requires connection to the mains 2 1 To...

Page 9: ...nces and the space available in your installation TYPE A Installation TYPE B Installation The cell and the electronic control unit are assembled together The cell and the electronic control unit are m...

Page 10: ...ct this water when cutting 5 Do not under any circumstances use power tools to cut the PVC pipe Use a hand saw Please note that the QUICKSALT chlorinator must always be installed after the pump and fi...

Page 11: ...inside 4 Apply cleaner between the ends resulting from the cut and the points marked as B Also clean the fittings to be glued Be sure to choose the right ones for your pipe two sets of sizes are prov...

Page 12: ...other Choose the correct position according to your hydraulic system so that water enters the cell through the deflector marked IN and exits through the one marked OUT Note The arrow in the picture ab...

Page 13: ...he anchoring accessories located at the back of the control unit Make sure there is no excessive distance so that the extension cable allows you to connect correctly b Connect the extension cable betw...

Page 14: ...85 72 1 2 3 4 29 28 58 53 1 2 3 4 5 19 18 43 40 1 2 3 4 5 6 16 15 40 36 Close by flow rise Open by flow decrease Note An excessively long paddle in a high water flow would reduce the life of the sens...

Page 15: ...ave checked that the hydraulic installation does not present any losses you can connect your QUICKSALT chlorinator to the electrical control panel Attention Disconnect the power supply to the panel be...

Page 16: ...rinators which you will find in shops specializing in swimming pool products Add the salt directly to the vessel of the pool It is recommended to add it progressively in 2 3 times waiting for it to di...

Page 17: ...by adjusting the production of the equipment and the hours of operation How you can make such an adjustment is detailed in later sections The most important recommended chemical parameters are shown b...

Page 18: ...nd 2 ppm of Cl2 per day to keep the water disinfected and in perfect condition for a pleasant use by the users a good starting point would be 60 and from here adjust the appropriate one There are 3 mo...

Page 19: ...ll contents of the settings you can make Please read the following sections carefully to learn more about their functionality 4 2 Navigation Left arrow Go back in the navigation and reduce the value t...

Page 20: ...in this area of the screen Prod 100 17 0V Status OK 70 F By pressing the right button you will access the configuration menu If you want to make a setting first go to the screen where the parameter yo...

Page 21: ...ore frequent cleaning decrease the time between cleanings or increase it This value can be adjusted from 2h very hard water to 8h soft water Note that more frequent self cleaning cycles mean shorter e...

Page 22: ...s If that happens you may need to adjust the self cleaning system to a higher frequency decrease the time between cleanings When the cell has reached its useful life you will notice that the equipment...

Page 23: ...s salt in the water Add water from the network to lower the salt concentration Water too cold Water temperature bellow 50 F 10 0 C Stop production When the temperature exceeds 59 F 15 C production is...

Page 24: ...in the filtration position Air accumulation in the upper part Let it expel itself Purge if necessary Open circuit The cell electrodes are misplaced Place the electrodes correctly one per vessel slot...

Page 25: ...for warranty service If a written proof of the purchase is not given the manufacturing data will be the determinant of the date of installation of the product The warranty covers any manufacturing de...

Page 26: ...unit 1 QS Control Electrolysis cell 1 Cell RP35QS 10K Cell RP25QS 10K Cell RP15QS 10K Cell housing 1 QS Vaso Racord 2 101N976 Mounting clamps 2 101N910 Installation Template 1 QS Template Cell cable e...

Page 27: ...MANUAL DE USUARIO 27...

Page 28: ...U S Office 1680 Michigan Avenue suite 700 Miami Beach Florida 33139...

Reviews: