6. Warnings and Alarms
The unit will display a warning if the salinity conditions of your pool water are outside the
optimum operating range. In the event of a warning, production does not stop*, but it is advisable
for the user to take corrective action as soon as possible.
Message
Cause
Corrective Action
Lack of salt
Lack of salt in the water
Add more salt
Incrustations in the cell
Reduce the time between cleanings.
Manual cleaning of the cell if
necessary
Depleted Cell
Replace the electrolysis cell
with a new
Excess salt
Excess salt in the water
Add water from the network to
lower the salt concentration
*Water too cold
Water temperature bellow 50° F
(10
0
C). Stop production.
When the temperature exceeds 59° F
(15 °C), production is restored again.
Cleaning
The equipment is performing a
cleaning cycle
None
production is restored again. This feature extends the lifespan of the Cell.
Additionally, a pass-through kit (sold separately)
is available, which allow you to continue
running water through the plumbing without the
Electrolytic Cell in place.
It can be useful in case your installation does
not have a plumbing by-pass system, and it is
necessary to remove the cell system from the
installation for maintenance purposes.
*Quicksalt will stop production if Water too cold is detected.