WARNING:

Please read carefully and thoroughly.

Australian Standard AS 1670.6 states the purpose of

installing smoke alarms is to provide early warning of a

potentially life threatening condition and provide the

maximum possible exit time. 

Smoke alarms have sensing limitations. Ionisation

sensing alarms may detect invisible fire particles

(associated with fast flaming fires) sooner than

photoelectric alarms. Photoelectric sensing alarms may

detect visible fire particles (associated with slow

smoldering fires) sooner than ionisation alarms. Home

fires develop in different ways and are often

unpredictable. 

For maximum protection, both

ionisation and photoelectric alarms should be

installed.

A battery powered alarm must have a battery of the

specified type, in good condition and installed properly.

AC powered alarms (without battery backup) will not

operate if the AC power has been cut off, such as by

an electrical fire or an open fuse.

Smoke alarms must be tested regularly to make sure

the batteries and the alarm circuits are in good

operating condition.

Smoke alarms cannot provide an alarm if smoke does

not reach the alarm. Therefore, smoke alarms may not

sense fires starting in chimneys, walls, on roofs, on the

other side of a closed door or on a different floor.

If the alarm is located outside the bedroom or on a

different floor, it may not wake up a sound sleeper.

The use of alcohol or drugs may also impair one’s

ability to hear the smoke alarm. For maximum

protection, a smoke alarm should be installed in each

sleeping area on every level of a home.

Although smoke alarms can help save lives by

providing an early warning of a fire, they are not a

substitute for an insurance policy. Home owners,

landlords and tenants should have adequate insurance

to protect their lives and property.

IMPORTANT:

This alarm is not intended to alert hearing

impaired individuals.

Fire Safety

2

Summary of Contents for QM10

Page 1: ...re often unpredictable For maximum protection against fast flaming fires and slow smouldering fires both ionisation and photoelectric alarms should be installed Copyright 2020 carrier All rights reser...

Page 2: ...tallation and keep thismanual near the alarm for future reference 1 Manufactured in China for Chubb Fire Security Pty Ltd Telephone 1800 654 435 Website www quell com au 2 Troubleshooting 11 12 Produc...

Page 3: ...nting Smoke from a fire will rise to the ceiling and spread horizontally Mounting the smoke alarm in the centre of the ceiling places it closest to all points in the room When mounting an alarm on the...

Page 4: ...tric Type Smoke Alarms for Additional Protection KITCHEN BEDROOM BEDROOM BEDROOM LIVING ROOM KITCHEN BEDROOM BEDROOM HALL BASEMENT FIGURE 1A FIGURE 1C FIGURE 1B SINGLE FLOOR PLAN MULTIPLE FLOOR PLAN B...

Page 5: ...lation Figure 2A 2 Figure 2B NOT IN THIS AREA ANYWHERE IN THIS AREA NOT IN THIS AREA ANYWHERE IN THIS AREA PEAK CEILING SLOPED CEILING 500mm 1000mm 1000mm 500mm DEAD AIR DEAD AIR DO NOT INSTALL DO NOT...

Page 6: ...e temperatures may fall below 5 or rise above 40 or in humidity higher than 85 These conditions will reduce battery life or cause an alarm fault 5 In extremely dusty dirty or insect infested areas The...

Page 7: ...the bracket and turn the alarm body clockwise until matching well on the bracket Press the test button on the unit The alarm sounds 3 beeps 1 5 seconds pause repeats until button is released if no sou...

Page 8: ...7 Installation Figure 3E 2...

Page 9: ...ble shooting section for solution NOTE WEEKLY TESTING IS REQUIRED LED indicators Red LED Flashing once every 40 seconds indicates that the smoke alarm device is operating properly Red LED Flashing whe...

Page 10: ...illing frying Using the fan on a range hood that vents to outside non recirculating type will also help remove these combustible particles from the kitchen The alarm silence test button is extremely u...

Page 11: ...th red LED flashes on ceevery 40 seconds The battery is under low battery status please replace the smoke alarm device Smoke alarm device chirp occurs every 40 seconds alarm goes into fault mode Clean...

Page 12: ...efective battery or other failures you can refer to Trouble shooting for solution if there are still failures during warranty you can return to your retailer WARNING The battery is sealed in cover and...

Page 13: ...will not operate if the AC power has been cut off such as by an electrical fire or an open fuse Smoke alarms must be tested regularly to make sure the batteries and the alarm circuits are in good oper...

Page 14: ...t including basements exception In existing one and two family dwelling units approved smoke alarms powered by batteries are permitted Smoke Detection Are more smoke alarms desirable The required numb...

Page 15: ...hen the Alarm Sounds Alert small children in the home Leave immediately by your escape plan Every second counts so don t waste time getting dressed or picking up valuables In leaving don t open any in...

Page 16: ...of acceptable quality and the failure does not amount to a major failure Exclusions Subject to non excludable laws this warranty does not cover normal wear and tear to the product or parts batteries o...

Page 17: ...ease provide the original or a copy of the proof of purchase Also please make sure you have included an explanation of the problem If elects to repair the product please note that goods presented for...

Reviews: