Power Supply Ratings
Table 27: The Module Power Supply Ratings
5.2.
Operation and Storage Temperatures
The operation and storage temperatures are listed in the following table.
Table 28: Operation and Storage Temperatures
Parameter
Min.
Typ.
Max.
Unit
Operation Temperature Range
1)
-
35
+25
+75
ºC
Extended Operation Range
2)
-
40
+85
ºC
Parameter
Description
Conditions
Min.
Typ.
Max.
Unit
VBAT
VBAT_BB and
VBAT_RF
The actual input voltages
must stay between the
minimum and maximum
values.
3.4
3.8
4.3
V
Voltage drop during
burst transmission
Maximum power control
level on EGSM900.
400
mV
I
VBAT
Peak supply current
(during transmission
slot)
Maximum power control
level on GSM900.
1.8
2.0
A
USB_VBUS
USB detection
3.0
5.0
5.25
V