LPWA Module Series
BG770A-GL Hardware Design
BG770A-GL_Hardware_Design 16 / 75
1.
1)
When the module starts up normally, to ensure full-function mode, the minimum power supply
voltage should be higher than 3.1 V.
2.
2)
Within the operating temperature range, the module meets 3GPP specifications.
3.
3)
Within the extended temperature range, the module remains the ability to establish and maintain
functions such as voice*, SMS and data transmission, without any unrecoverable malfunction. Radio
spectrum and radio network are not influenced, while one or more specifications, such as P
out
, may
exceed the specified tolerances of 3GPP. When the temperature returns to the operating temperature
range, the module meets 3GPP specifications again.
Debug UART:
Used for firmware upgrade, software debugging and log output
115200 bps baud rate by default
The default frame format is 8N1 (8 data bits, no parity, 1 stop bit)
Support RTS and CTS hardware flow control
AUX UART:
Used for RF calibration debugging and log output
921600 bps baud rate by default
The default frame format is 8N1 (8 data bits, no parity, 1 stop bit)
Supports RTS and CTS hardware flow control
GNSS*
GPS, GLONASS
AT Commands
3GPP TS 27.007 and 3GPP TS 27.005 AT commands
Quectel enhanced AT commands
Network Indication
One NET_STATUS pin for network connectivity status indication
Antenna Interfaces
Main antenna (ANT_MAIN) and GNSS antenna (ANT_GNSS) interfaces
Physical Characteristics
Dimensions: (14.9 ±0.2) mm × (12.9 ±0.2) mm × (1.9 ±0.2) mm
Package: LGA
Weight: TBD
Temperature Range
Operating temperature range: -35 °C to +75 °C
2)
Extended temperature range: -40 °C to +85 °C
3)
Storage temperature range: -40 °C to +90 °C
Firmware Upgrade
Debug UART
DFOTA*
RoHS
All hardware components are fully compliant with EU RoHS directive.