NB-IoT Module Series
BC26 AT Commands Manual
BC26_AT_Commands_Manual 55 / 73
6
General Commands
The AT command names listed below are temporary, and may be changed in the future release.
6.1. AT+QBAND Query Current Operating Band
This command is used to query current modem NB-IoT operating band.
Parameter
6.2. AT+QRESET Reset UE
This command is used to reset the module immediately.
AT+QBAND Query Current Operating Band
Read Command
AT+QBAND?
Response
+QBAND: <Current Band>
OK
If there is any error, response:
ERROR
Test Command
AT+QBAND=?
Response
+QBAND=
(list of supported
<Current Bands>
s)
OK
<Current Band>
Integer, valid values : 1, 2, 3, 5, 8, 12, 13, 17, 18, 19, 20, 26, 28, 66
AT+QRESET Reset UE
Write Command
AT+QRESET=<mode>
Response
OK