NOTE:
* Command classes on endpoints are supported securely only if the device is added to a Z-Wave
network as secure.
NOTE:
•
Endpoints are shown/hidden by Parameter No. 100
•
The relays will be turned ON or OFF after receiving the BASIC_SET command.
•
To be turned ON: [Command Class Basic, Basic Set, Basic Value = 0x01~0x63; FF]
•
To be turned OFF: [Command Class Basic, Basic Set, Basic Value = 0x00]
•
BASIC SET/GET on root device is mapped to basic set/get of both endpoints.
COMMAND_CLASS_METER_V1
•
Default values:
o
Rate Type = 1 (Import)
o
Scale = 0 (W)
This Security Enabled Z-Wave Plus Product can be included and operated in any Z-Wave
network with other Z-Wave certified devices from any other manufacturers and product
categories. All constantly powered nodes in the same network will act as repeaters regardless
of the vendor in order to increase reliability of the network.