QS-210
6.
ADVANCED APPLICATIONS
INFO
Examples shown in this section describes optional application of external safety
and power cut-off devices. If you wish to expand the functionality of your motion
system, read the whole section to have a good understanding of how to apply
and what functionality to expect. Apply at your own discretion.
WARNING
Motion Lock input is not a SIL/PL (safety integrity level/performance level) rated
and
DOES NOT
guarantee safety. If you wish to achieve specific SIL/PL ranking,
consider introducing a power cut-off device that is controlled by an external
safety relay and cuts off the power to all QS-SB2. Example application of the
power cut-off contactor can be found in section 6.3.2 and 6.3.3.
INFO
When applying safety relay to the Motion Lock :
■
Use input cables according to your safety relay manual.
■
Use output cables according to your safety relay manual and cross section
no less than 0,75 mm
2
6.1.
ADDING ADDITIONAL DEVICES TO THE MOTION LOCK CIRCUIT
If there is necessity to stop other devices, apart from the QS-210, ML (Motion Lock)
and additional user devices can be controlled by safety relay outputs. In the example
application, the E-STOP button is connected to the external safety relay. When the E-
STOP is triggered, the safety relay will activate the Motion Lock function, which will stop
motion of the platform and additional devices.
User Manual R1 09/2023
39
Summary of Contents for QS-210
Page 1: ......
Page 2: ......
Page 12: ...QS 210 2 2 EXTENSION SET LIST OF COMPONENTS User Manual R1 09 2023 12...
Page 21: ...QS 210 3 4 INTRO SET LAYOUTS User Manual R1 09 2023 21...
Page 25: ...QS 210 3 7 EXTENSION SET LAYOUTS User Manual R1 09 2023 25...
Page 26: ...QS 210 User Manual R1 09 2023 26...
Page 27: ...QS 210 3 8 EXTENSION SET CABLE CONNECTIONS User Manual R1 09 2023 27...
Page 29: ...QS 210 3 9 EXTENSION SET CONNECTING WITH TRACTION LOSS SYSTEM User Manual R1 09 2023 29...
Page 49: ......
Page 50: ......