5
TECHNICAL
DATA
Unit
QT10
QT20
QT30
Flow
rate
min
lph
(gpm)
5
(0.02)
20
(0.09)
200
(0.9)
max
@
1
mPas
lph
(gpm)
180
(0.8)
1200
(5.3)
5000
(22)
max
@
500
mPas
lph
(gpm)
120
(0.5)
700
(3.1)
4000
17.6)
max
@
1.000
mPas
lph
(gpm)
50
(0.2)
500
(2.2)
3500
(15.4)
Pressure
<40°C
barg
(psig)
6
(87)
6
(87)
6
(87)
>40°C
barg
(psig)
4
(58)
4
(58)
4
(58)
max.
Temperature
Process
°C
(°F)
80
(176)
80
(176)
80
(176)
CIP
°C
(°F)
90
(194)
90
(194)
90
(194)
SIP
°C
(°F)
125
(257)
125
(257)
125
(257)
Connector
Type
1/4"
TC
3/4"
TC
1
‐
1/2"
TC
Product
Wetted
Pump
chamber
316L*
316L*
316L*
Materials
Valves
EPDM
EPDM
EPDM
(Standard)
Diaphragm
Santoprene
Santoprene
Santoprene
O
‐
Rings
EPDM
EPDM
EPDM
Motor
Type
AC
motor
AC
motor
AC
motor
Pump
Speed
Range
rpm
75
‐
3000
50
‐
2400
30
‐
1200
Rated
Speed
@50Hz
rpm
2800
1370
1440
Voltage
V
220
‐
240/380
‐
420 220
‐
240/380
‐
420
220
‐
240/380
‐
420
Power
kW
(HP)
0.37
(0.5)
0.37
(0.5)
2.2
(3)
Forced
Cooling
Fan
V
no
230V
230V
Dimensions
Length
mm
(in.)
335
(13.19)
487
(19.17)
777
(30.59)
Width
mm
(in.)
139
(5.47)
159
(6.26)
288
(11.34)
Height
mm
(in.)
199
(7.83)
194
(7.64)
341
(13.43)
Weight
kg
(lb.)
10
(22)
18
(40)
85
(187)
Typical
dispensing
accuracy
<
60
l/h
<
2%
<
200
l/h
<
2%
<
500
l/h
<
2%
(with
AC
Motor)
>
60l/h
<
1%
>200
l/h
<
1%
>500
l/h
<
1%
*
Surface
finish
0,8
µm
(32
µin.)
All
mentioned
technical
data
refers
to
the
standard
versions.
Summary of Contents for QT 10
Page 7: ...QT 30 0 psii 43 p psi 87 psi 7...
Page 17: ...17 Pump chamber incl connections QT10 C Drive unit QT10 A...
Page 20: ...20 Components QT20 Drive unit A ring drive B pump chamber C Ring drive QT20 B...
Page 21: ...21 Pump chamber incl connections QT20 C Drive unit QT20 A...
Page 24: ...24 Components QT30 Drive unit A ring drive B pump chamber C base plate D Ring drive QT30 B...
Page 25: ...25 Pump chamber incl connections QT30 C Drive unit and base plate QT30 A D...