4.5

 

Flow directions 

Due  to  the  internal  check  valves  inside  the  pump  liquid  cannot  flow  backwards  through  the  pump.  Please 
mind this if the installation needs to be emptied through the pump. 
Note: The flow direction is independent from the direction of motor rotation. 
 
 

4.6

 

Product connections 

 

Suction  and  discharge  connections  of  sizes  QF150  and  QF1200  are  mounted 
opposite at the pump chamber (“inline”). An arrow on the pump chamber shows 
the  flow  direction  (see  figure),  so  that  the  suction  and  pressure  side  can  be 
clearly identified. 
 
The  size  QF4400,  QF5050  and  QF20K  have  both  ports  in  front  of  the  pump 
chamber and are marked with "IN" (inlet) and "OUT" (outlet). 
 

 
Please see the drawings below for Quattroflow pump chamber orientation which are supplied as standard ex 
works. All QF pump chambers can be rotated in 90° steps to adapt the pump to your process and application. 
The orientation has no influence on the self-venting behavior.  
See also chapter Drainability of Quattroflow Pumps. There you can find further information about the pump 
chamber orientation for best drainability. 
 

Standard port and pump chamber orientation from factory: 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

In case that the pump chambers should be rotated: 
Please mind that the clamp ring needs to be rotated as well to access the clamping ring 
screw (see installation instructions in the user manual). 
If the clamping ring screw is not fixed before operation the pump could be damaged. 

 

QF150 

QF1200 

Figure 6 Standard pump chamber orientation for Quattroflow pumps. 

Summary of Contents for QF1200

Page 1: ...Quattroflow Installation Operation Troubleshooting Guide Version Rev 0 July 2017...

Page 2: ...et line 10 4 3 Protection from high pressure 10 4 4 High inlet pressure 10 4 5 Flow directions 11 4 6 Product connections 11 5 Start up operations 12 5 1 Mounting the pump 12 5 2 Mounting the pump cha...

Page 3: ...Quattroflow Installation Operation Troubleshooting Guide Rev 0 Page 3 of 25 www quattroflow com Revision Date Changes Comment Issued by 0 July 2017 First Release Tim Dudda...

Page 4: ...ch application and it gives important points for consideration for planned systems For end users we bring together topics like installation operation and maintenance We want to ensure a safe and relia...

Page 5: ...plasma products therapeutic proteins monoclonal antibodies vaccines and other high value products Technical definition Reciprocating positive displacement pumps Diaphragm pump membrane pump The Quattr...

Page 6: ...flow rate and discharge pressure The pump speed is directly related to the flow rate The following factors influence the correlation between pump speed and flow rate Back pressure Medium density and v...

Page 7: ...ct the Quattroflow Team to get more information and support The chemical resistance depends on some factors like mixture concentration temperature and standing time In case that the chemical resistanc...

Page 8: ...resistance of some selected mediums Please note that this table is for indication only and needs to be verified with the actual medium in the process 3 2 Solids and suspensions Solid particles should...

Page 9: ...Please make sure that the pump is always operated in the linear range of the performance curve see Figure 4 If the pump is operated at higher motor speeds outside the linear flow range damage of diap...

Page 10: ...ly equivalent with the internal diameter form the pump connector If the inner diameter of the outlet line is too small the pump performance is limited Make sure that the outlet pipe or hose is safe ag...

Page 11: ...e pump chamber and are marked with IN inlet and OUT outlet Please see the drawings below for Quattroflow pump chamber orientation which are supplied as standard ex works All QF pump chambers can be ro...

Page 12: ...is built on ex works If you have ordered a Quattroflow Single Use Pump or just a Single Use pump chamber the chamber will be supplied separately The front crews and the clamping ring screw have to be...

Page 13: ...ccentric shaft Min pump speed for self venting at free output Min flow rate for self venting at free output QF150 5 ca 1000 rpm ca 75 l h QF1200 5 Standard ca 500 rpm ca 300 l h QF1200 3 ca 900 rpm ca...

Page 14: ...as active CIP pump Depending on the products in contact with the pump and given requirements the cleaning procedure needs to be adapted accordingly It is the responsibility of the user to verify the...

Page 15: ...e fluid path through the pump is only open in flow direction from inlet to outlet connection port It is not possible to rinse the pump in reversed flow direction because the check valve will not open...

Page 16: ...pressure barg 89 0 1 170 0 1 348 0 1 516 0 3 680 0 5 840 0 6 Table 8 Pressure drop of QF1200 pump chamber at different flow rates Water RT Pump size QF4400 QF5050 Pressure sensor 2 Flow rate l h Diffe...

Page 17: ...um SIP cycles depends on further process conditions e g medium temperature flow rate back pressure Condensate removal after SIP process After SIP process Quattroflow pumps may contain a non recoverabl...

Page 18: ...utlet of the pump e g by connecting hoses Ensure that a free interchange of gas and steam over a sterile barrier e g sterile filter at in and outlet is available 5 Autoclaving of the prepared pump cha...

Page 19: ...F150 and QF1200 we recommend a vertically mounted pump chamber inlet up outlet down for optimized drainability The shown standard orientation for QF4400 QF5050 and QF20K pump series is also the recomm...

Page 20: ...de Rev 0 Page 20 of 25 www quattroflow com QF4400 QF5050 QF20K Standard orientation Optimized drainability Pump drive horizontally standard inlet up outlet down standard Table 11 Standard and optimize...

Page 21: ...t and the outlet site of the pump chamber for draining after the process or cleaning procedure is finished For new or existing Quattroflow pump with gear motors there are some points which have to be...

Page 22: ...of 25 www quattroflow com QF4400 QF20K Full drainability Pump drive Vertically Pump chamber downwards Figure 9 QF4400 and QF20K orientation for full drainability Please contact the support team to ge...

Page 23: ...ts to warm Too high pulsation Diaphragm damage X X The front screws of the pump chamber pressure plate are not tightened enough Fix it with the defined tightened torque X Check the direction of flow s...

Page 24: ...gm is burst replace with respective elastomer service kit X X X X O rings between valve plate and pump housing are defective Replace with respective elastomer service kit X X The clamping ring screw g...

Page 25: ...g Guide Rev 0 Page 25 of 25 www quattroflow com Subject to change without notice ALMATEC Maschinenbau GmbH Carl Friedrich Gauss Str 5 47475 Kamp Lintfort Germany Telephone 49 2842 9610 Telefax 49 2842...

Reviews: