![Quattroflow 5050SU Operating And Installation Instructions Download Page 17](http://html1.mh-extra.com/html/quattroflow/5050su/5050su_operating-and-installation-instructions_3555291017.webp)
QF5050SU; edition 2016-05; page 17 of 18
7. Technical data of the QF 5500S
Description Unit
QF5050SU
Flow rate max.:
Eccentric shaft 6°
l/h
(gph)
5000
(1321)
Flow rate min.:
Eccentric shaft 6°
l/h
(gph)
50
(13)
Pressure:
Temperature of fluid < 40°C
bar
(psi)
4
(58)
Temperature of fluid > 40°C
bar
(psi)
4
(58)
Temperature max.:
Fluid
°C
(°F
) 60
(140)
Autoclave
°C
(°F
) 130
(260)
Suction lift dry at:
1200rpm
Eccentric shaft 6°
m
(ft)
4-4,5
(13.1-14.7)
Volume specifications:
Approximated volume per revoulution at free output
ml
95
Filling volume without connectors
ml
820
Residual volume (after idle with high-speed motor)
ml
ca. 0-80; depends on
installation position
Product wetted surface (approx.)
cm²
(inch²)
1669
(259)
Speed range pump
rpm
1-1285
Connection specification inlet (standard)
Connector
" 1,5"
TC
Flange diameter
mm
(inch)
50,5
Internal diameter
mm
(inch)
34
Connection specification outlet (standard)
Connector
" 1,5"
TC
Flange diameter
mm
50,5
Internal diameter
mm
(inch)
34
(1.34)
Position of connectors
Front
Diameter drive shaft
mm
28
Product wetted materials (standard):
Pump housing
PP
Valve plate
PP
Diaphragms
TPE
Valves
EPDM
O-rings
EPDM
Non-product wetted materials (standard):
Diaphragm cover
PP
Bearing housing
SS316L
Base plate
SS316
Hood
SS316
Dimensions pump with motor and housing:
Length
mm
(inch)
440
(17.32)
Width
mm
(inch)
325
(12.80)
Height
mm
(inch)
320
(12.60)
Weight pump with motor and housing
kg
(lb)
51
(113)
Custom tarif number
84138100
Certificates/proofs (optional):
Elastomere (product wetted)
USP <88> Cl. VI;
FDA21CFR177;
BSE/TSE Safe