background image

QUATRO         

Air Technologies Inc.

 

---------------------------------------------------------

Engineers Of Clean Air

 --------------------------------------------------------

 

30 Hymus Boulevard, Montreal, Quebec, H9R 1C9     Tel.: (514) 630-4444   Fax: (514) 630-4454   website: 

www.quatroair.com

   [email protected] 

 

 

 

 

 

          

 

Light Diagnostics Table G16.13 or G17.13 and higher 

Light 

Led1 

System 

ON 

Led2 

Service 

Motor 

Led3 

Service 

Filter 

Led4 
Filter 

Clean 

Led5 

Remote/ 

Standby 

Audible 

Alert 

Condition 

Action 

 

System 

Operation 

SOLID 

 

 

 

 

None 

Unit is operating using POWER 

button on panel, no remote signal 

Remote or mc2 has a shutdown delay of approximately 5-10 

seconds 

 

Fading 

 

 

 

 

 

Temporary ON mode 

Pressing the POWER button while Led5 is Flashing will temporarily 

disable any active remote standby. 

ONLY main motor is operational, to do temporary cleaning using 

dust collector. 

To Re-Establish STANDBY turn the unit off using the POWER 

button. 

 

SOLID 

 

 

 

SOLID 

None 

 

Unit is operating using remote 

signal 

 

 

SOLID 

 

 

 

Fading 

IN-OUT 

None 

Shutdown delay 

(Remote signal has been removed) 

Remote has a shutdown delay of approximately 5-10 seconds 

 

 

 

 

 

Flashing 

None 

Unit is in Standby mode, waiting for 

remote signal (or mc2 signal if 

provided) to start unit 

 

Low 

System 

Pressure 

Flashing Flashing  Flashing 

 

Flashing  Beep Every 

Second 

Abnormally Low  Pressure, Unit will 

BEEP until addressed 

Check motor(s), Check motor brushes, verify if filters are installed, 

close all filter access points, 

(available only on JS-5222, not on JS-5200) 

Service 

Motors 

 

SOLID 

 

 

 

Beep Every 

4 Hours 

50 hrs of life left in brushes 

Replace motors. Reset Motor Life Alert 

120v-PN: AR175 or 230v-PN: AR176

 

Service 

Filters 

 

 

Flashing 

 

 

None 

Filter Pressure High 

Prepare To Replace/Service Filters 

(available only on JS-5222, not on JS-5200) 

 

 

 

Flashing 

 

 

Beep Every 

Hour 

Filter Pressure Close To Critical 

Replace/Service Filters Now. Continued Operation may Result In 

Unit Shutdown, (available only on JS-5222, not on JS-5200) 

 

 

 

Flashing 

 

 

Beep Every 

Second 

Critical Pressure, Unit BEEPING 

CONSTANTLY 

Verify Blockage, Verify All Filters 

(available only on JS-5222, not on JS-5200) 

 

 

 

SOLID 

 

 

Beep Every 

Hour 

Replace Filter (s) ASAP 

Replace Filter (s) ASAP 

 

Summary of Contents for CollectALL MedEVAC MultiPure PowerStation PS2

Page 1: ...unit 6 ft long hose INSTALLATION 1 Open filter door remove plastic around HEPA filter and Odor Filter if applicable 2 Ensure filter bags are properly installed fit into 2 tubes beneath the top of fil...

Page 2: ...companies shipping documents Single box c w all components required either on or inside the unit PRE START UP CHECKLIST a Check that all internal components are present and are adequately supported b...

Page 3: ...t stops BEEPING 8 Led will be OFF and unit will be ready to operate again BLOWER MAINTENANCE INFINITY MOTORS NO BRUSH CHANGE REQUIRED This unit is equipped with an Automatic Motor Optimization System...

Page 4: ...et design See the beginning of the Motor Service Replacement Section 5 Install the bracket on the new motor If the bracket is installed incorrectly it may result in a short to ground for the brush con...

Page 5: ...r s Led stays SOLID 4 While motor is operating press hold SPEED UP DN simultaneously until unit BEEPS hold for 10 seconds when beeping continuously release 5 In this condition System ON Led is FLASHIN...

Page 6: ...sed to assume for QUATRO any other liability in connection with the sale of these goods Equipment parts and material manufactured by others and incorporated in QUATRO s equipment are warranted by QUAT...

Page 7: ...ming Urgent Replace Filters See Filter Service Replacement For More Info Continued Operation May Result In Unit Shutdown High Pressure Causes Excess Motor Heat Accelerates Brush Wear Flashing Slowly B...

Page 8: ...n removed Remote has a shutdown delay of approximately 5 10 seconds Flashing None Unit is in Standby mode waiting for remote signal or mc2 signal if provided to start unit Low System Pressure Flashing...