QUATRO
Air Technologies Inc.
---------------------------------------------------------
Engineers Of Clean Air
--------------------------------------------------------
30 Hymus Boulevard, Montreal, Quebec, H9R 1C9 Tel.: (514) 630-4444 Fax: (514) 630-4454 website:
www.quatroair.com
Light Diagnostics Table G16.13 or G17.13 and higher
Light
Led1
System
ON
Led2
Service
Motor
Led3
Service
Filter
Led4
Filter
Clean
Led5
Remote/
Standby
Audible
Alert
Condition
Action
System
Operation
SOLID
None
Unit is operating using POWER
button on panel, no remote signal
Remote or mc2 has a shutdown delay of approximately 5-10
seconds
Fading
Temporary ON mode
Pressing the POWER button while Led5 is Flashing will temporarily
disable any active remote standby.
ONLY main motor is operational, to do temporary cleaning using
dust collector.
To Re-Establish STANDBY turn the unit off using the POWER
button.
SOLID
SOLID
None
Unit is operating using remote
signal
SOLID
Fading
IN-OUT
None
Shutdown delay
(Remote signal has been removed)
Remote has a shutdown delay of approximately 5-10 seconds
Flashing
None
Unit is in Standby mode, waiting for
remote signal (or mc2 signal if
provided) to start unit
Low
System
Pressure
Flashing Flashing Flashing
Flashing Beep Every
Second
Abnormally Low Pressure, Unit will
BEEP until addressed
Check motor(s), Check motor brushes, verify if filters are installed,
close all filter access points,
(available only on JS-5222, not on JS-5200)
Service
Motors
SOLID
Beep Every
4 Hours
50 hrs of life left in brushes
Replace motors. Reset Motor Life Alert
120v-PN: AR175 or 230v-PN: AR176
Service
Filters
Flashing
None
Filter Pressure High
Prepare To Replace/Service Filters
(available only on JS-5222, not on JS-5200)
Flashing
Beep Every
Hour
Filter Pressure Close To Critical
Replace/Service Filters Now. Continued Operation may Result In
Unit Shutdown, (available only on JS-5222, not on JS-5200)
Flashing
Beep Every
Second
Critical Pressure, Unit BEEPING
CONSTANTLY
Verify Blockage, Verify All Filters
(available only on JS-5222, not on JS-5200)
SOLID
Beep Every
Hour
Replace Filter (s) ASAP
Replace Filter (s) ASAP