background image

2

3

The CO2 is controlled 

via the gas canister 

regulator on the front 

of the unit (see dia-

gram). 

Use a large flathead 

screwdriver or a 19mm 

spanner to increase 

the level of carbonation 

in the water. Turn the 

regulator by a half turn 

in a clockwise direction.

To decrease the level of carbonation, turn the 

regulator by a half turn in an counter-clockwise 

direction.

Between adjustments, 

you must run off sev-

eral glasses of spar-

kling water to see the 

effects of the adjust-

ment. If the sparkling 

function is spluttering, 

there is too much gas in 

the water. Reduce the 

setting by one full turn 

and try again.

TAP FUNCTIONS:
ADJUSTING THE CARBONATION OF 
THE SPARKLING WATER

ADJUSTING CARBONATION - CHANGING CO2 CANISTER

CO

2

TAP FUNCTIONS:
SPARKLING WATER 
CHANGING THE CO2 CANISTER

When the sparkling water tastes flat, it is nec-

essary to change the gas canister.

The integral CO2 gas canister is sited on the 

left-hand side at the front of the unit (see dia-

gram opposite).

Please follow the instructions below to ensure 

your CO2 canister is correctly installed:

1. To remove a canister, unscrew in a counter-

clockwise direction.

2. Locate the thread on the regulator where the

gas canister will connect.

3. Carefully present the canister, ensuring the 

canister is supported. 

4. Rotate the canister in a clockwise direction, 

being careful not to cross thread the regulator.

**see next page illustration.

FRONT VIEW

Counter-Clockwise

CO

2

REGULATOR THREAD

CO

2

For your safety and to prevent accidental use, 

the boiling function has a safety switch that 

needs to be released to activate the flow of 

boiling water. 

1. Press and release boiling 

(red)

.

2. Dispense hot water in 6 secs and automati-

cally stop. 

3. To turn this function off, press and release 

boiling 

(red)

 again. To end this function before 

the 6 second timer ends, press and release any 

button.

QUATREAU SMART TAP

QUATREAU SMART TAP

BOILING WATER

CHILLED WATER AND 

SPARKLING WATER

DIGITAL BUTTON

DIGITAL BUTTON

To activate chilled water:

1. Press and release chilled (middle blue button).

2. This will dispense chilled water for 6 seconds 

then automatically stop.

3. To end this function before the 6 second tim-

er ends, press and release any button.

To activate sparkling water 

1. Press and release sparkling (Right Blue But-

ton).

2. This will dispense Sparkling water for 6 sec-

onds then automatically stop.

3. To end this function before the 6 second tim-

er ends, press and release any button.

SPARKLING WATER

SAFETY SEQUENCE - ACTIVATE CHILLED & SPARKLING - DIGITAL BUTTON

Reviews: