TIMTER™ Multi
-mode Dual
Telemetry Transmitter
65
Quasonix, Inc.
Mnemonic
Command
Name
Description
Option (s)
Required
Setting
Saved?
Factory
Default
SW
Frequency
Sweep
Sweeps the transmitter frequency
between provided limits, with
provided step size, at a fixed rate
Enables independent channel
sweep and start/stop (individually
or together); Channel 3 sets both
channels
Examples:
SW
Displays current status
SW ? Displays command help
with status
SW [chan]
Toggles the
channel sweep state
SW 1 2200.5 2394.5 1.0
Sweep channel 1
between 2200.5 MHz and 2394.5
MHz in 1.0 MHz steps
Standard
N/A
N/A
SY
System Status
Displays the system status of the
transmitter
The first argument specifies the
period, in milliseconds, between
status updates. Zero (0) disables
continuous monitoring.
The second argument specifies
the number of status lines
between header outputs.
Examples:
SY
Displays current status
report settings
SY 5
Sets status output period
to 5 milliseconds
SY 5 100
Sets status
header output once every 100
status updates
Refer to section 4.2.3.1.3 for
additional SY command detail
Standard
N/A
N/A