TIMTER™ Multi
-mode Dual
Telemetry Transmitter
43
Quasonix, Inc.
Mnemonic
Command
Name
Description
Option (s)
Required
Setting
Saved?
Factory
Default
DIN
Display Machine
Data Input
Registers
This is a read only command;
Displays the machine data input
registers as one or more of two
blocks specified by one hex
character
Each bit is one block
1 = DIN 0,
2 = DIN 1
R is register:
C - Control
F - Clock free control
R - Rate readback
S - Rate set
P - KP
I - KI
Value is 32 bit register value
Example:
DIN ? Displays registers
Standard
DIOR
Display I/O
Register
Addresses
Displays I/O addresses of
machine registers to make it
easier to debug with IR and IW
commands
Example:
DIOR Displays I/O addresses
DL
DAC Level
This is a read only command
;
Displays digital DAC level internal
to the transmitter
Valid range is 1 to 16383
Example:
DL
Display DAC level