TIMTER™ Multi
-mode Dual
Telemetry Transmitter
46
Quasonix, Inc.
Mnemonic
Command
Name
Description
Option (s)
Required
Setting
Saved?
Factory
Default
FR
Frequency
If no argument is passed, it
reports the frequency. If an
argument is passed, it sets the
frequency. The argument
specifies the frequency in MHz. If
the command is entered with a
‘?’, then the allowed frequency
ranges for this unit display.
This command rounds the
frequency to the nearest 0.5 MHz.
If the rounded frequency is within
one of the transmitter’s allowed
bands, the transmitter will tune
that frequency and confirm the
change for the user.
If the frequency is outside of the
allowed range for the unit, the
transmitter will NOT retune but
will report an error to the user.
Examples:
FR
Display the current
frequency
FR ?
Display allowed
frequency ranges
FR 1436.5
Set frequency to
1436.5 MHz
Standard
Y
FR
1436.5
FS
Frequency Step
If no argument is passed, it
reports the current frequency
step. If an argument is passed, it
sets the frequency step size,
which is activated by the left and
right square bracket keys. The
argument specifies the frequency
step in MHz, with 0.5 MHz being
the smallest available step.
Examples:
FS
Display the current
frequency step
FS 1
Frequency step = 1 MHz
Standard
Y
FS 1