TIMTER™ Multi-mode Digital Telemetry Transmitter
79
Quasonix, Inc.
Requirement
Description
RE102
Radiated Emissions, Electric Field
RS101
Radiated Susceptibility, Magnetic Field
RS103
Radiated Susceptibility, Electric Field
Quasonix transmitters have been tested for compliance with these standards approximately annually since 2004.
However, such testing is only performed as part of a qualification program, and the test results are the exclusive
property of the customer who paid for them. If you need EMI testing on a particular part number, please contact
[email protected] for a quote.
6.4 Carrier Frequency Tuning
The carrier frequency is selectable in 0.5 MHz steps. Frequencies supported by TIMTER™ transmitters are listed in
Table 17.
Table 17: Carrier Frequencies (MHz)
Band ID
Code
Band
Minimum
Freq
Maximum
Freq
Default Freq
Tuning
Steps
Max
Power
A
Lower S
2200.5 MHz
2300.5 MHz
2250.5 MHz
0.5 MHz
25 W
B
Mid C and Euro Mid C
5091.0 MHz
5250.0 MHz
5120.0 MHz
0.5 MHz
20 W
C
C “Low”
4400.0 MHz
4950.0 MHz
4620.0 MHz
0.5 MHz
20 W
D
C (with Mid C)
4400.0 MHz
and
5091.0 MHz
4950.0 MHz
and
5150.0 MHz
4620.0 MHz
0.5 MHz
20 W
E
(all) L, S, C
1435.5 MHz
1750.0 MHz
2200.5 MHz
2300.5 MHz
4400.0 MHz
5091.0 MHz
5150.0 MHz
1534.5 MHz
1855.0 MHz
2300.5 MHz
2394.5 MHz
4950.0 MHz
5150.0 MHz
5250.0 MHz
2370.5 MHz
0.5 MHz
10 W
F
S and C
2200.5 MHz
and
4400.0 MHz
2394.5 MHz
and
4950.0 MHz
2370.5 MHz
0.5 MHz
20 W
G
Euro Mid C
5150.0 MHz
5250.0 MHz
5150.0 MHz
0.5 MHz
20 W
H
L and C
1435.5 MHz
and
4400.0 MHz
1534.5 MHz
and
4950.0 MHz
1450.5 MHz
0.5 MHz
10 W