TIMTER™ Multi-mode Digital Telemetry Transmitter
39
Quasonix, Inc.
Mnemonic
Command
Name
Description
Option (s)
Required
Setting
Saved?
Factory
Default
CS
Clock Source
Report or set the clock source
Unit always reverts to CS 0
(external) at power-up
Examples:
CS
Display the current clock
source
CS 0
Set clock source to
external
CS 1
Set clock source to
internal
When set to internal clock source,
the data source must also be set
to internal via the DS command in
order to have synchronous,
usable data.
Also refer to Appendix C
Understanding Clock/Data, AC,
and BR
Standard
N
CS 0
DE
Differential
Encoding
Report or set differential encoding
for the SOQPSK-TG or other
PSK mode
(Differential encoding typically
disabled for other modes)
If LDPC enabled, DE resets to 0.
DE is not valid with MC enabled.
Examples:
DE
Report the differential
encoding setting
DE 0
Set differential encoding
OFF
DE 1
Set differential encoding
ON
Standard
Y
DE 1
DIOR
Display I/O
Register
Addresses
Displays I/O addresses of
machine registers to make it
easier to debug
Example:
DIOR Displays I/O addresses
Standard
N/A
N/A