Quasar HQ-2101SH Operating Instructions Manual Download Page 5

OFF

LOW

COOL

LOW

FAN

HIGH

FAN

HIGH

COOL

THERMOSTAT

10

9

8

7

6

5

4

3

1

2

AIR SWING

ON

OFF

2

AIR CONDITIONER INST

ALLA

TION

Air inlet louver

Air filter

Cabinet

Front intake grille

Power cord

Front grille

Vertical airflow direction vane

(Airflow direction adjustment up-down).
The vertical airflow direction vane is controlled by
rotating the horizontal vane forward or backward.

3

P

A

R

T

 IDENTIFICA

TION

MAIN UNIT

Ventilation lever

The ventilation lever must be in the CLOSE position in order to maintain the best cooling
conditions. When fresh air is necessary in the room, set the ventilation lever to the OPEN
position. The damper is opened and room air is drawn out.

1

2

3

4

5

6

8

7

9

a

b

c

1

Remove the rubber plug and
slide the chassis out from the
cabinet.

Remove the
rubber plug

2

Install the optional drain pan (part no. CWH40175).

Screws

INTERNAL VIEW

Drain pan (optional)

Install the drain pan at the
right corner of the cabinet
using 2 screws (part no.
CWG86C733).

3

Connect a drain hose (optional).
Fit the drain hose to the drain pan.

EXTERNAL VIEW

Under-side view with drain
pan and hose in place.

Drain hose
(not included)

4

Slide the chassis back
into the cabinet.
Reinstall the cabinet to
chassis by using screws.

NOTE
The drain pan (part no.
CWH40175) can be
obtained from nearest
servicenter.

NOTE
Drain hose or tubing can be
purchased locally to satisfy
your particular needs.

THERMOSTAT

10

9

8

7

6

5

4

3

1

2

HIGH

COOL

OFF

LOW

COOL

LOW

FAN

HIGH

FAN

AIR SWING

ON

OFF

TH

AIR SWIN

G

ON

OFF

OFF

LOW

COOL

LOW

FAN

HIGH

FAN

HIGH

COOL

THERMO

STAT

10

9

8

7

6

5

4

3

1

2

AIR SWING

ON

OFF

Main control panel

Air Swing Switch

OFF Stops the operation of Air Swing.
ON

Air Swing is in operation.
(Only for LOW COOL, MED COOL, HIGH COOL and ECONOMY
operation.)

Main Control Knob

Stops all operation

Low fan speed operation (without cooling)

High fan speed operation (without cooling)

Low fan speed with cooling operation

High fan speed with cooling operation

Thermostat Control Knob

For decreased cooling

For increased cooling

HOW TO ATTACH THE DRAIN PAN (OPTIONAL)

Summary of Contents for HQ-2101SH

Page 1: ...I O N E R F563445 Please read these operating instructions thoroughly before using your air conditioner and keep them for future reference ENGLISH For assistance please call 1 800 211 PANA 7262 or se...

Page 2: ...a long period Pay attention to any damages on the unit caused by extensive usage Ventilate the room occasionally where the unit is installed Remove the power plug when cleaning the unit CAUTION 2 AIR...

Page 3: ...ge of the bottom window sash Window sash sealing ribbon 1 Slide the chassis into the cabinet 2 Reinstall the cabinet screws Secure the cabinet to chassis by using screws from rear cabinet NOTE This pr...

Page 4: ...the right until right tab releases c c c c c At the bottom left side push inward on cabinet and pull the grille outward to the left to release the left tab Do not pull thebottomedgetowardyoumorethan3i...

Page 5: ...the cabinet using 2 screws part no CWG86C733 3 Connect a drain hose optional Fit the drain hose to the drain pan EXTERNAL VIEW Under side view with drain pan and hose in place Drain hose not included...

Page 6: ...hes 37 5 14 25 32 Width cm inches 56 22 1 16 Depth cm inches 60 6 23 27 32 NET WEIGHT kg lb 35 77 GROSS WEIGHT kg lb 39 86 NOISE LEVEL Indoor Hi Lo dB A 50 46 51 47 Outdoor Hi Lo dB A 57 54 58 55 1 Op...

Page 7: ...center 8 BEFORE CALLING FOR SERVICE Check the following points before calling for repairs or service If the malfunction persists please contact your nearest servicenter For assistance please call 1 80...

Page 8: ...supplied by the warrantor or failures which result from accident misuse abuse neglect mishandling misapplication faulty installation maladjustment of customer controls improper maintenance alteration...

Page 9: ...as instrucciones detenidamente antes de utilizar el aparato de aire acondicionado y gu rdelas como referencia para el futuro Para solicitar asistencia llame al tel fono al cliente 1 800 211 PANA 7262...

Page 10: ...o por un uso intensivo Ventile la habitaci n ocasionalmente Desenchufe al aparato de la red antes de proceder a su limpieza AVISO 2 INSTALACI N DEL APARATO DE AIRE ACONDICIONADO Debido al peso de este...

Page 11: ...Vuelve a colocar los tornillos del armario Fije el armario al chasis con los tornillos del armario trasero NOTA Este procedimiento se aplica a derecha e izquierda del panel extensible de montaje Una e...

Page 12: ...c c En el lado inferior izquierdo presione hacia dentro y tire de la rejilla hacia fuera a la izquierda para soltar la pesta a izquierda d d d d d Deslice la rejilla frontal hacia arriba para liberar...

Page 13: ...drenaje opcional Coloque la manguera de drenaje en la bandeja de drenaje VISTA EXTERNA Vista inferior con bandeja de drenaje y manguera colocadas Manguera de drenaje no incluida 4 Deslice el chasis h...

Page 14: ...6 23 27 32 PESO NETO kg lb 35 77 PESO BRUTO kg lb 39 86 NIVEL DE RUIDOS Interior Alto bajo dB A 50 46 51 47 Exterior Alto bajo dB A 57 54 58 55 1 Abra la tapa del panel de control 2 Alimentaci n de c...

Page 15: ...nes o mantenimiento Si el fallo de funcionamiento persiste p ngase en contacto con un servicio t cnico Para solicitar asistencia llame al tel fono 1 800 211 PANA 7262 o env e un correo electr nico a c...

Page 16: ...supplied by the warrantor or failures which result from accident misuse abuse neglect mishandling misapplication faulty installation maladjustment of customer controls improper maintenance alteration...