Quasar ARM User Manual Download Page 9

calibration mode, while the user has about 4 seconds to spend 
a few times a piece of ferrite over the coil. A small piece of 
ferrite should be used, and do not bring it close to the sensor. 
The angle of response from it will be calculated, but to save 
this setting, you must click the OK button. When exiting “Esc”, 
the setting is not remembered. 

>> For RK instruments, the value is usually in the range from -
20 to -45. Also, after automatic calibration, I strongly 
recommend manual calibration so that there is no response to 
ferrite, the average size of a copper coin was about 80-81 
according to VDI, a piece of foil 1.5x1.5 cm (not a lump) was 
about 0 by VDI, and 5 kopecks of the USSR about 50 by VDI. 
Remember - the correct ferrite setting is the key to the correct 
operation of the device. Values need to be adjusted manually 
+ \ - a few points, for example, auto-tuning set the value to -
30, save the settings, exit the operating mode, wave the 
ferrite - there is a weak response, wave the copper coin, for 
example, the value for VDI is +85, we return to the settings 
and reduce the value to -29, save and exit to operating mode, 
wave with ferrite - it is not voiced, the copper coin became 
valid +83 by VDI, return to the ferrite calibration menu and set 
the value to -28, save, exit, wave copper coin - the result is 80-
81, and then 5 kopecks of the USSR, foil, etc., in general, 
ferrite calibration is a matter of experience, if the ferrite is not 
set correctly, the device may not see large copper targets at a 
depth, giving false positives for strikes and show other 
negative phenomena. Understanding this setting is the key to 
a comfortable and productive search. 

Summary of Contents for ARM

Page 1: ...QUASAR user guide...

Page 2: ...f the device 3 OK button enter button for the soil balance menu 4 Left button backlight on off button 5 Button 6 Right button pinpoint call button 7 Cancel button and button to enter the device menu 8...

Page 3: ...ly replaced by the value of the soil balance in the format 0 0 and the value of the current value in the TX in the format 00 mA the value of the supply voltage is displayed in the format 0 0V In the o...

Page 4: ...ttom line is the value of the current angle of the soil response in degrees The manual angle can be changed using the Left and Right buttons the step is 0 1 degrees Raising and lowering the sensor sho...

Page 5: ...he finer or deeper the target the quieter the sound of the target The larger the target or the less its depth the louder the sound The range of change is 1 7 The buttons Left and Right decrease and in...

Page 6: ...bove 41 in high tone Scheme 3 Goals below 90 are voiced in low tone above 90 in high tone Threshold Thrashhold Background sound in the absence of a target under the sensor voiceover of clean soil Off...

Page 7: ...frequency transmitter frequency It is in the standard range of 70 0 MHz 108 0 MHz It is necessary to choose a free frequency so as not to listen to coin signals on the chanson fm wave It should also b...

Page 8: ...he Right and Left buttons OK exit with saving the result Esc exit without saving When powered by two Li ION batteries connected in series set the value to 6 0V Ferrite calibr ferrite calibration Allow...

Page 9: ...ferrite setting is the key to the correct operation of the device Values need to be adjusted manually a few points for example auto tuning set the value to 30 save the settings exit the operating mode...

Page 10: ...er in the second line B Balance D Desired balance N No compensator Desired balance value of the desired sensor balance level The amplitude and phase value are set to which the auto compensator needs t...

Page 11: ...y saved settings from the profile Menu item BACKLIGHT LEVEL SCREEN BACKLIGHT LEVEL Backlight Setting the brightness level of the backlight 0 off 100 the highest brightness Change the value with the bu...

Page 12: ...the soil allows you to reduce the effect of soil on the input of the device slightly increase the depth of the search and also helps to configure the detector for the best scanning speed by the searc...

Page 13: ...level from the target bottom right alternating values current in the sensor in mA ground balance and battery voltage in V Signograph is the same as the previous menu item only without VDI value VDI is...

Page 14: ...memorize the mask you must press the OK button when exiting by Esc changes are not remembered Checkers displays a sector that will not be voiced SPEED OF GEB GROUND ADJUSTMENT SPEED Autotrack speed s...

Page 15: ...FAST fast To memorize a value it is necessary to press the OK button when exiting via Esc changes are not remembered...

Reviews: