Quasar ARM User Manual Download Page 8

while the current consumption of the TX output stage (in mA) 
is also displayed on the screen. When you press any of the Up 
or Down buttons, the device switches to the mode of 
automatic selection of the resonant frequency according to 
the maximum current of the output stage. To save this setting, 
click the “OK” button. When exiting “Esc”, the setting is not 
remembered. 

Voltmeter - correction of the battery level indication. The 
voltmeter value is changed using the "Right" and "Left" 
buttons. “OK” - exit with saving the result, “Esc” - exit without 
saving. 

U min — Sets the threshold for the low battery warning. The 
value is changed using the "Right" and "Left" buttons. “OK” - 
exit with saving the result, “Esc” - exit without saving. When 
powered by two Li-ION batteries connected in series, set the 
value to 6.0V 

Ferrite calibr ferrite calibration. Allows you to set the initial 
value (ZERO) of the VDI scale. Take the angle of response from 
ferrite as 0 degrees (if in very simple words, it allows the 
device to understand where copper is, where ferrous metal, 
etc.). Manual mode is possible, in which the “Left” and “Right” 
buttons set the angle of rotation (delay) in degrees. In this 
case, the response level is displayed in the upper line, moving 
a piece of ferrite over the coil, and changing the angle of 
rotation, it is necessary to achieve a minimum deviations of 
the level indicator from 0. By pressing any of the Up or Down 
buttons, the device switches to the automatic ferrite 

Summary of Contents for ARM

Page 1: ...QUASAR user guide...

Page 2: ...f the device 3 OK button enter button for the soil balance menu 4 Left button backlight on off button 5 Button 6 Right button pinpoint call button 7 Cancel button and button to enter the device menu 8...

Page 3: ...ly replaced by the value of the soil balance in the format 0 0 and the value of the current value in the TX in the format 00 mA the value of the supply voltage is displayed in the format 0 0V In the o...

Page 4: ...ttom line is the value of the current angle of the soil response in degrees The manual angle can be changed using the Left and Right buttons the step is 0 1 degrees Raising and lowering the sensor sho...

Page 5: ...he finer or deeper the target the quieter the sound of the target The larger the target or the less its depth the louder the sound The range of change is 1 7 The buttons Left and Right decrease and in...

Page 6: ...bove 41 in high tone Scheme 3 Goals below 90 are voiced in low tone above 90 in high tone Threshold Thrashhold Background sound in the absence of a target under the sensor voiceover of clean soil Off...

Page 7: ...frequency transmitter frequency It is in the standard range of 70 0 MHz 108 0 MHz It is necessary to choose a free frequency so as not to listen to coin signals on the chanson fm wave It should also b...

Page 8: ...he Right and Left buttons OK exit with saving the result Esc exit without saving When powered by two Li ION batteries connected in series set the value to 6 0V Ferrite calibr ferrite calibration Allow...

Page 9: ...ferrite setting is the key to the correct operation of the device Values need to be adjusted manually a few points for example auto tuning set the value to 30 save the settings exit the operating mode...

Page 10: ...er in the second line B Balance D Desired balance N No compensator Desired balance value of the desired sensor balance level The amplitude and phase value are set to which the auto compensator needs t...

Page 11: ...y saved settings from the profile Menu item BACKLIGHT LEVEL SCREEN BACKLIGHT LEVEL Backlight Setting the brightness level of the backlight 0 off 100 the highest brightness Change the value with the bu...

Page 12: ...the soil allows you to reduce the effect of soil on the input of the device slightly increase the depth of the search and also helps to configure the detector for the best scanning speed by the searc...

Page 13: ...level from the target bottom right alternating values current in the sensor in mA ground balance and battery voltage in V Signograph is the same as the previous menu item only without VDI value VDI is...

Page 14: ...memorize the mask you must press the OK button when exiting by Esc changes are not remembered Checkers displays a sector that will not be voiced SPEED OF GEB GROUND ADJUSTMENT SPEED Autotrack speed s...

Page 15: ...FAST fast To memorize a value it is necessary to press the OK button when exiting via Esc changes are not remembered...

Reviews: