4.  Configuration (via USB on Windows PC) 

The free configuration software is on the CD provided and is downloadable from www.quark-elec.com. 

 
 

 

Figure 5: AS08 3-Axis Compass configuration Tool

 

 

1.  Open the configuration tool 

2.  Select your 

COM port number

 

3. 

Click ‘

Open

’. Now, ‘

Connected

’ will show on the bottom left side of the configuration tool and the 

configuration tool is ready to be used 

4. 

Click ‘

Read

’ to read the devices current settings 

5. 

Configure the settings as desired: 

 

 Select the 3D Model. 

 The configuration tool can be used to monitor the real time attitude of 

the object. The AS08 has been designed for the marine market, but it can be used on vehicle 
or aircraft models. Users can choose a proper 3D module for their application. The real time 
attitude  will  be  shown  on  the  left-hand  side  window.  Please  note,  some  computers  without 
dedicated GPU (Graphics Processing Unit) 

can’t support this function.  

If the NMEA 0183 format data needs to be output to any other third-party software/APP, 

‘None’ 

should be selected here, the NMEA  0183 data will be sent out through the USB and NMEA 
0183  ports  simultaneously.  The  user  can  use  any  USB  port  monitor  software  to  observe  or 
record the data on PC or OTG (the baud rate should be set to 115200bps in this case). 

 

 Output messages

 are set to transmit all data types as a default setting. However, the AS08 

has an internal filter, so the user can remove unwanted NMEA 0183 message types. 

 

 

 Data  output  frequency

  is  set  to  transmit  at  1Hz  (once  per  second)  as  default.  Heading 

messages (HDM and HDG) can be set to 1/2/5/10 times per second. Rate of turn, roll and pitch 
can only be set at 1Hz.  

 

NMEA 0183 baud rates

.

 

‘Baud rates’ refer to the data transfer speed. The AS08’s output port 

default  baud  rate  is  4800bps.  However,  the  baud  rate  can  be  configured  to  9600bps  or 
38400bps if required. 

When connecting two NMEA 0183 

devices, both devices’ baud rates, must be set to the same 

speed. Select the baud rate to match your chart plotter or connecting device. 

 

LED brightness level. 

Three-digit LED on the panel will show the real time heading information. 

The user can adjust the brightness for day or night use. It can also be turned off to save power.  

 

Summary of Contents for QK-AS08

Page 1: ... and USB port Displays the heading data on the panel Up to 10Hz update rate for heading Super electromagnetic compatibility Enables 0 4 compass heading accuracy and 0 6 pitch and roll accuracy Calibratable to compensate for magnetic deviation caused by ferrous metals and other electro magnetic fields very rarely required we only provide this function to our authorised distributors Low 100mA power ...

Page 2: ...ng AS08 via USB for Windows configuration 5 3 1 1 Will you need a driver to connect via USB 5 3 1 2 Checking the USB COM port Windows 5 4 Configuration via USB on Windows PC 6 4 1 NMEA 0183 wiring RS422 or RS232 7 5 Data Output Protocols 7 6 Specification 8 7 Limited warranty and notices 8 8 Disclaimer 8 9 Document history 8 10 For more info 8 ...

Page 3: ...outputting this information You can filter out this message type if not required using the Windows configuration tool with AS08 The AS08 outputs the NMEA 0183 format data via USB and RS422 port Users can easily connect it to their computer or NMEA 0183 listeners to share information with navigational software chart plotters autopilots vessel data recorder and dedicated instrument displays 2 Instal...

Page 4: ...the configuration tool to setup NMEA 0183 output data type baud rate and data frequency 12V DC needs to be connected to power up the AS08 Figure 2 QK AS08 Wire Function Red 12V Black GND Green NMEA output Yellow NMEA output USB port The AS08 is supplied with a type C USB connector This connector is used to connect the AS08 directly to a PC which allows for data transfer to the PC This port is also...

Page 5: ...SB The AS08 registers itself to the computer as a virtual serial COM port If the driver does not install automatically it can be found on the included CD and downloaded from www quark elec com 3 1 2 Checking the USB COM port Windows After the driver is installed if needed run the Device Manager and check the COM port number The port number is the number assigned to an input device These can be gen...

Page 6: ...ird party software APP None should be selected here the NMEA 0183 data will be sent out through the USB and NMEA 0183 ports simultaneously The user can use any USB port monitor software to observe or record the data on PC or OTG the baud rate should be set to 115200bps in this case Output messages are set to transmit all data types as a default setting However the AS08 has an internal filter so th...

Page 7: ...Although the AS08 sends out NMEA 0183 sentences via differential end RS422 interface it also supports single end for RS232 interface devices these wires need to be connected QK AS08 wire Connection needed on RS422 device NMEA 0183 NMEA output GND 2 NMEA output NMEA Input POWER Black GND GND for Power Red Power 12v 14 4v Power 2 Swap NMEA input and GND wires if the AS08 does not work 5 Data Output ...

Page 8: ...cover failures due to abuse misuse accident or unauthorised alteration or repairs A returns number must be given before any unit is sent back for repair The above does not affect the statutory rights of the consumer 8 Disclaimer This product is designed to aid navigation and should be used to augment normal navigational procedures and practices It is the user s responsibility to use this product p...

Page 9: ...QK AS08 Manual V 1 0 9 of 9 2021 Quark elec UK Unit 7 the Quadrant Newark Close Royston UK SG8 5HL info quark elec com ...

Reviews: