QK-AS08 Manual
V 1.0
4 of 9
2021
•
Do NOT install near ferrous metals
or anything that can create a magnetic field such as:
magnetized materials, electric motors, electronic equipment, engines, generators, power/ignition
cables, and batteries.
If you believe your AS08 isn’t accurate please contact your distributor to re-
calibrate your device.
3. Connections
The AS08 sensor has the following connections.
•
NMEA 0183 port and power
. A four-core M12 connector can be connected with the provided 2-
meter cable. This can be connected to the NMEA 0183 listeners and the power supply. The user
can use the configuration tool to setup NMEA 0183 output data type, baud rate and data
frequency.
12V DC needs to be connected to power up the AS08.
Figure 2 QK-AS08
Wire
Function
Red
12V
Black
GND
Green
NMEA
Yellow
NMEA output
–
•
USB port. The AS08 is supplied with a type C USB
connector. This connector is used to connect the
AS08 directly to a PC which allows for data transfer to
the PC. This port is also used to configure and
calibrate the AS08 (The calibration function is only
provided to authorised distributors).
The USB port can also be used to observe the target
attitude with the configuration tool. The configuration
tool provides vessel, aircraft and vehicle 3D models
(dedicated GPU is needed for this function). If the
3D module is set as
‘None’, the NMEA 0183 format
Figure 3: 3D Model