Quark-Elec QK-AS08 Manual Download Page 5

 

 

 

QK-AS08 Manual                           

 

 

 

V 1.0 

5 of 9 

2021 

 

data will be sent out through USB and NMEA 0183  port simultaneously. The user can use any 
USB port monitor software (e.g. OpenCPN) to observe or record the data on PC or OTG (the baud 
rate should be set to 115200bps for this function).  

 

3.1.  Connecting AS08 via USB for Windows configuration  

3.1.1.  Will you need a driver to connect via USB? 

 
In  order  to  enable  the  USB  data  connection  of  the  AS08,  related  hardware  drivers  may  be  needed 
dependent on your system requirements. 
 
For Windows versions 7 and 8, a driver will be needed for configuration but for Windows 10, the driver 
usually  installs  automatically.  A  new  COM  port  will  automatically  show  up  in  the  device  manager  once 
powered and connected via USB. 
 
The AS08 registers itself to the computer as a virtual serial COM port.  
If  the  driver  does  not  install  automatically,  it  can  be  found  on  the  included  CD  and  downloaded  from 
www.quark-elec.com. 

3.1.2.  Checking the USB COM port (Windows) 

 
After the driver is installed (if needed), run the Device Manager and check the 

COM (port) number

. The 

port  number  is  the  number  assigned  to  an  input  device.  These  can  be  generated  randomly  by  your 
computer. 
The configuration software will require a COM port number in order to access the data.  
 
The port number can be found in Windows ‘Control Panel>System>Device Manager’ under ‘Ports (COM 
& LPT)’. Find something similar to ‘USB-SERIAL CH340’ in the list for the USB port. If the port number 
needs to be changed for some reason, double click the icon in the list 

and select the ‘Port Settings’ tab. 

Click the ‘Advanced’ button and change the port number to the one required. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 4: View of COM port in Device Manager 

Summary of Contents for QK-AS08

Page 1: ... and USB port Displays the heading data on the panel Up to 10Hz update rate for heading Super electromagnetic compatibility Enables 0 4 compass heading accuracy and 0 6 pitch and roll accuracy Calibratable to compensate for magnetic deviation caused by ferrous metals and other electro magnetic fields very rarely required we only provide this function to our authorised distributors Low 100mA power ...

Page 2: ...ng AS08 via USB for Windows configuration 5 3 1 1 Will you need a driver to connect via USB 5 3 1 2 Checking the USB COM port Windows 5 4 Configuration via USB on Windows PC 6 4 1 NMEA 0183 wiring RS422 or RS232 7 5 Data Output Protocols 7 6 Specification 8 7 Limited warranty and notices 8 8 Disclaimer 8 9 Document history 8 10 For more info 8 ...

Page 3: ...outputting this information You can filter out this message type if not required using the Windows configuration tool with AS08 The AS08 outputs the NMEA 0183 format data via USB and RS422 port Users can easily connect it to their computer or NMEA 0183 listeners to share information with navigational software chart plotters autopilots vessel data recorder and dedicated instrument displays 2 Instal...

Page 4: ...the configuration tool to setup NMEA 0183 output data type baud rate and data frequency 12V DC needs to be connected to power up the AS08 Figure 2 QK AS08 Wire Function Red 12V Black GND Green NMEA output Yellow NMEA output USB port The AS08 is supplied with a type C USB connector This connector is used to connect the AS08 directly to a PC which allows for data transfer to the PC This port is also...

Page 5: ...SB The AS08 registers itself to the computer as a virtual serial COM port If the driver does not install automatically it can be found on the included CD and downloaded from www quark elec com 3 1 2 Checking the USB COM port Windows After the driver is installed if needed run the Device Manager and check the COM port number The port number is the number assigned to an input device These can be gen...

Page 6: ...ird party software APP None should be selected here the NMEA 0183 data will be sent out through the USB and NMEA 0183 ports simultaneously The user can use any USB port monitor software to observe or record the data on PC or OTG the baud rate should be set to 115200bps in this case Output messages are set to transmit all data types as a default setting However the AS08 has an internal filter so th...

Page 7: ...Although the AS08 sends out NMEA 0183 sentences via differential end RS422 interface it also supports single end for RS232 interface devices these wires need to be connected QK AS08 wire Connection needed on RS422 device NMEA 0183 NMEA output GND 2 NMEA output NMEA Input POWER Black GND GND for Power Red Power 12v 14 4v Power 2 Swap NMEA input and GND wires if the AS08 does not work 5 Data Output ...

Page 8: ...cover failures due to abuse misuse accident or unauthorised alteration or repairs A returns number must be given before any unit is sent back for repair The above does not affect the statutory rights of the consumer 8 Disclaimer This product is designed to aid navigation and should be used to augment normal navigational procedures and practices It is the user s responsibility to use this product p...

Page 9: ...QK AS08 Manual V 1 0 9 of 9 2021 Quark elec UK Unit 7 the Quadrant Newark Close Royston UK SG8 5HL info quark elec com ...