3.3.  Connect Via USB to Windows Computer 

 
The AS07-0183 is designed to be used out of the box, for using.  
Alternatively, AS07-0183 can be connected via USB adaptor(optional) to a Windows PC for: 
 
1, Outputting GPS sentence to PC via USB port.  
2, Filtering of NMEA 0183 output sentences, to eliminate unwanted data.  
3, Adjusting the data band rate and data output frequency (data transferred once per second). The 
frequency can be set to 1/2/5/10 per second. 1Hz is the default setting and is generally recommended. 
Please note: 10 Hz may cause data overflow in some devices.  
 
 
 
 
 

 

Figure 4 RS232 to USB adaptor 

Only three wires need to be connected to USB adaptor as below to get the connection work.  
 

AS07-0183 

USB adaptor

TX 

RX

RX 

TX

GND 

GND

 
 

 

Figure 5 AS07-0183 to USB adaptor 

  Will you need a driver to connect via USB? 

To enable the USB data connection of AS07-0183, related hardware drivers may be needed dependent 
on your system requirements. Please be noted, although AS07-0183 can be used on Mac and Linux 
system to output NMEA 0183 data via USB, the configuration tool can only be run on Windows based 
system.  
 

Mac:

 

No driver required. For Mac OS X, the AS07 will be recognized and shown as a USB modem. The ID 
can be checked with the following steps: 

1.  Plug the AS07 into a USB port and launch Terminal.app.  

Summary of Contents for QK-AS07-0183

Page 1: ...tion update rate as default setting up to 10 Hz rapid position update rate Many formats of NMEA data output user can configure through Windows configuration tool Configurable baud rates 4800 9600 38400 115200 bps through the Windows Configuration tool Ultra low 35mA power consumption at 12V DC Support USB output via USB adaptor included IPX6 waterproof enclosure ...

Page 2: ...s 4 3 1 Connect two NMEA 0183 devices RS232 5 3 2 Connect to NMEA 0183 devices RS422 5 3 3 Connect Via USB to Windows Computer 6 Will you need a driver to connect via USB 6 Checking the USB COM Port Windows 7 4 The Configuration tool Windows PC 8 4 1 Optional NMEA 0183 configuration 8 5 Data Output Protocols 9 6 Specification 9 7 Limited Warranty and Notices 9 8 Disclaimer 9 9 Document History 10 ...

Page 3: ...es additional configurations Filtering of desired NMEA 0183 sentences to eliminate unwanted data Adjusting the frequency of NMEA 0183 output rate 1 2 5 10 per second Adjusting the data output baud rate 4 8k 9 6k 38 4k 115 2k bps 1 2 GPS Glonass and Galileo GNSS The AS07 0813 receives and process messages from GPS Galileo and Glonass positioning satellites GPS Galileo and Glonass are all space sate...

Page 4: ...screw thread The AS07 0183 can be installed using the corresponding antenna base included or a G 3 4 Base of your choice 2 2 Operation The AS07 0183 is designed to be used out of the box for instant positional data to other NMEA 0183 device The default baud rate has been set as 4800bps at 1Hz updating frequency 3 Connections The AS07 0183 sensor has the following five wires shield wire 12V GND GND...

Page 5: ...GND some time called COM 3 2 Connect to NMEA 0183 devices RS422 Although AS07 0183 sends out NMEA 0183 sentences via single end RS232 interface it supports most of RS422 interface differential signal in the market Two wires need to be connected as below QK AS07 0183 RS422 interface devices TX NMEA OUT NMEA IN some times called NMEA B Ve GND and GND shield NMEA IN sometimes called NMEA A Ve Try to ...

Page 6: ...y cause data overflow in some devices Figure 4 RS232 to USB adaptor Only three wires need to be connected to USB adaptor as below to get the connection work AS07 0183 USB adaptor TX RX RX TX GND GND Figure 5 AS07 0183 to USB adaptor Will you need a driver to connect via USB To enable the USB data connection of AS07 0183 related hardware drivers may be needed dependent on your system requirements P...

Page 7: ...r does not install automatically it can be found on the included CD and downloaded from www quark elec com Checking the USB COM Port Windows After the driver is installed if needed run the Device Manager and check the COM port number The port number is the number assigned to an input device These can be generated randomly by your computer The Configuration software will require a COM port number i...

Page 8: ...on tool is read to be used 4 Click Read to read the device s current settings 5 Configuring the settings NMEA 0183 Baud Rates Baud rates refer to the data transfer speed AS07 0183 s output port s default baud rate is 4800bps however the baud rate is configurable if required When connecting two NMEA 0183 devices both devices baud rates must be set to the same speed Select the baud rate to match you...

Page 9: ... date of purchase Quark elec will at its sole option repair or replace any components that fail in normal use Such repairs or replacement will be made at no charge to the customer for parts and labour The customer is however responsible for any transportation costs incurred in returning the unit to Quark Elec This warranty does not cover failures due to abuse misuse accident or unauthorized altera...

Page 10: ...tial release 10 For more info For more technical information and other enquiries please go to the Quark elec forum at https www quark elec com forum For sales and purchasing information please email us info quark elec com Quark elec UK Unit 7 the Quadrant Newark close Royston UK SG8 5HL info quark elec com ...

Reviews: