Quark-Elec AS07-N2K Manual Download Page 9

 

 

 

QK-AS07-N2K Manual                           

 

 

 

V 1.0 

9 of 12 

2021 

 

  Optional NMEA 2000 configuration 

 
The configuration tool must be used with a windows PC via USB cable.  
 
The configuration tool must not be opened while other programs are using the AS07-N2K.  
 

1.  Disconnect AS07-N2K from the backbone 

2.  Connect AS07-N2K to AS07-C (through NMEA 2000 connector), 

switch AS07-C to 

Config

 

 

3.  AS07-C must to be powered through 12V power. Connect 12V and GND 

4.  Connect to a Windows computer via USB. (Once any necessary drivers have been installed, 

AS07-N2K will be shown as a virtual com in device manager.) 

5.  Open the Configuration tool 

6.  Select your COM port number 

7.  Click 

Open

Now, ‘Connected’ will show on the bottom left side of the configuration tool and the 

Configuration tool is read to be used 

8. 

Click ‘

Read

’ to read the device’s current setting

s. 

9. 

Configuring NMEA 2000 settings 

 

Select ‘

2000

’ in 

System Config

 

Data Output frequency

 is set to transmit at 

1Hz (1 time per second) as default. This can be 
set to 1/2/5/10 times per second 

1Hz is the default setting and is generally 
recommended. Please note: 10 Hz may cause 
data overflow on the NMEA 2000 system 

 Output messages are set to transmit all data 

types as a default setting. However, the AS07-N2K has an internal filter, so the user can 
remove unwanted PGN message types

 

 

10.  C

lick ‘

Config

’.

 After a few seconds your settings will now be saved and you can close the 

Configuration tool 

11.  Click 

Close

’ under Com Setup, and click ‘

Exit

 

12.  Disconnect AS07-C from PC 

13.  Remove AS07-C power supply 

14. 

To return to NMEA 2000 use, disconnect from the AS07-C, and reconnect the AS07-N2K to 
the NMEA 2000 bus

 

 

  Configuring the AS07-N2K for backward compatibility with NMEA 0183 

devices  

 
The configuration tool must be used when plugged into a windows PC via USB cable.  
 
The configuration tool must not be opened while other programs are using the AS07.  
 

1.  Disconnect AS07-N2K from the backbone 

Summary of Contents for AS07-N2K

Page 1: ...nsor 1Hz position and heading update rate as default setting Enables 3 Compass Heading Accuracy Calibratable to compensate for magnetic deviation caused by ferrous metals and other electro magnetic fields very rarely required only provide this function to the authorized distributors Low 100mA power consumption at 12V DC IPX6 waterproof enclosure PLEASE NOTE AS07 N2K models from 15th May 2021 onwar...

Page 2: ...ugh the Windows Configuration tool Configurable filtering of data output protocols through the Windows Configuration tool NMEA 0183 compatible NMEA 0183 RS 422 Default NMEA 0183 baud rate set to 4800bps Configurable baud rates 4800 9600 38400 115200 bps through the Windows Configuration tool Calibratable to compensate for magnetic deviation very rarely required ...

Page 3: ...e Optional Output Switch 6 4 1 AS07 C Connections 7 4 2 Connecting AS07 C via USB for Windows Configuration 8 Will you need a driver to connect via USB 8 Checking the USB COM Port Windows 8 4 3 The Configuration tool Windows PC 8 Optional NMEA 2000 configuration 9 Configuring the AS07 N2K for backward compatibility with NMEA 0183 devices 9 4 4 NMEA 0183 wiring RS422 or RS232 10 5 Data Output Proto...

Page 4: ...cy of NMEA 2000 data 1 2 5 10 per second Calibratable to compensate for magnetic deviation very rarely required 2 Backward compatibility with NMEA 0183 devices 1 3 GPS Glonass and Galileo GNSS The AS07 N2K receives and process messages from GPS Galileo and Glonass positioning satellites GPS Galileo and Glonass are all space satellite based navigation systems also known as Global Navigation Satelli...

Page 5: ...passes standard and steering Minimum 2 meters from a VHF antenna Ensure the mounting location will not disrupt moving equipment eg Radar Do NOT install near ferrous metals or anything that can create a magnetic field such as magnetized materials electric motors electronic equipment engines generators power ignition cables and batteries Do not install within a steel magnetic container including not...

Page 6: ...work CAN The NMEA 2000 network allows multiple electronic devices to be connected together on a common channel for the purpose of easily sharing information Because it is a network and because multiple devices can transmit data a comprehensive set of rules dictates the behavior of the network devices The CAN automatically provides some of these rules for control of access to the network packet tra...

Page 7: ...ow on the NMEA 2000 system Calibratable to compensate for magnetic deviation very rarely required 2 Backward compatibility with NMEA 0183 devices 4 1 AS07 C Connections Figure 5 AS07 C Connections When used with the AS07 C instead of a NMEA 2000 connection the AS07 N2K with the AS07 C can have the following connections Power 12V and GND terminals need to be connected USB A type B micro USB connect...

Page 8: ...unning an original Windows 10 version A new COM port will automatically show up in the device manager once powered and connected via USB The AS07 N2K registers itself to the computer as a virtual serial com port If the driver does not install automatically it can be found on the included CD and downloaded from www quark elec com Checking the USB COM Port Windows After the driver is installed if ne...

Page 9: ...Select 2000 in System Config Data Output frequency is set to transmit at 1Hz 1 time per second as default This can be set to 1 2 5 10 times per second 1Hz is the default setting and is generally recommended Please note 10 Hz may cause data overflow on the NMEA 2000 system Output messages are set to transmit all data types as a default setting However the AS07 N2K has an internal filter so the user...

Page 10: ...ch your chart plotter or connecting device Data Output frequency is set to transmit at 1Hz 1 time per second as default This can be set to 1 2 5 10 times per second 1Hz is the default setting and is generally recommended Please note 10 Hz may cause data overflow on the NMEA 0183 device Output messages are set to transmit all data types as a default setting However the AS07 N2K has an internal filt...

Page 11: ...xxGLL Geographic Position Latitude and Longitude xxGSA GNSS DOP and Active Satellites xxGSV GNSS Satellites in View xxRMC Recommended Minimum Specific GNSS Data xxVTG Course Over Ground and Ground Speed xxZDA Time and Date xx above represents GP if GPS GL if GLONASS and GA if GALILEO xxHDG Heading with Deviation Variation xxHDM Heading Magnetic 6 Specification Item Specification Operating temperat...

Page 12: ...normal navigational procedures and practices It is the user s responsibility to use this product prudently Neither Quark elec nor their distributors or dealers accept responsibility or liability either to the products user or their estate for any accident loss injury or damage whatsoever arising out of the use or of liability to use this product Quark products may be upgraded from time to time and...

Reviews: