QK-AS07-N2K Manual
V 1.0
7 of 12
2021
•
Filtering of NMEA 2000 PGN messages, to eliminate unwanted data.
•
Adjusting the frequency of NMEA 2000 data. The default setting is 1 Hz (data
transferred once per second) The frequency can be set to 1/2/5/10 per second. 1Hz is
the default setting and is generally recommended. Please note: 10 Hz may cause data
overflow on the NMEA 2000 system.
•
Calibratable to compensate for magnetic deviation (very rarely required)
2. Backward compatibility with NMEA 0183 devices.
4.1. AS07-C Connections
Figure 5: AS07-C Connections
When used with the AS07-C, instead of a NMEA 2000 connection, the AS07-N2K with the AS07-C can
have the following connections:
•
Power:
12V and GND terminals need to be connected.
•
USB:
A type B micro-USB connection allows for connection to a PC. This connection is used to
adjust optional additional settings (see Configuration section).
Figure 4 AS07-C Dimensions