![Quantum Scalar i6000 Quick Start Manual Download Page 2](http://html2.mh-extra.com/html/quantum/scalar-i6000/scalar-i6000_quick-start-manual_3547634002.webp)
Q
UANTUM
S
CALAR
I
6000 & S
AFE
N
ET
K
EY
S
ECURE
Q
UICK
S
TART
G
UIDE
5
During the initialization process, you must have the following information:
•
An IP address for the KeySecure.
•
An IP address for the SSKM. This must be on the same subnet as the KeySecure IP.
•
The subnet mask for the network.
•
The gateway for the network.
•
A hostname for the KeySecure.
•
A port on the KeySecure on which the web administration occurs. The default port is 9443.
•
A port on the KeySecure on which KMIP communication occurs. We recommend port 5696, as this is
the standard created by IANA.
Secure the KeySecure
in a standard 19-inch rack that provides sufficient space at the front and rear for
cabling, airflow, and maintenance.
To mount the KeySecure:
1
Open the bezel
.
2
Position the rack mount brackets
to align with holes in the rack posts.
3
Use a screwdriver to
start the screws
into the mounting brackets.
Do not tighten
.
4
Properly
align the device
in the rack.
5
Use a screwdriver to
tighten the screws
. This should securely attach the mounting brackets to the
rack posts.
6
Connect the null modem cable to the serial port
on the back panel of the KeySecure. Plug the other
end of the null modem cable into the serial port of your console terminal or PC.
7
Connect the ethernet cable to the ethernet interface
on the back panel of the KeySecure. Plug the
other end of the ethernet cable to your network.
8
Connect the 9-pin Micro-D data cable to the PED port
on the back of the KeySecure. Plug the other
end of the data cable to the top of the PED.
9
Connect the power cable from the power supply
on the back panel of the KeySecure to an AC
power source. Unscrew the front plate to access the front panel components. Press the power switch
on the front panel. Reattach the front plate. The initial boot sequence and internal configuration can
take several minutes.
10
While the KeySecure performs the initial boot sequence,
start a terminal emulation session
using an
application such as HyperTerminal or Minicom. Use the following port settings:
-
VT100/ANSI
-
19200 bps
-
8 data bits
-
No parity