![Quantum RDX 8000 User Manual Download Page 77](http://html2.mh-extra.com/html/quantum/rdx-8000/rdx-8000_user-manual_3949456077.webp)
77
RDX 8000 User Guide
2. CRU replacement
2.1 Power supply
The power supply is a CRU (Customer Replaceable Unit). The power supply is located on the rear side of the unit and is
fixed with two thumb screws. The power supply is capable to power up to 8 cartridges simultaneously while supporting
other unit electronics (controller, LED`s, OCP, motors).
For technical specification, see section
“1. Product specification” on page 75
.
2.1.1 Removing a power supply
1. Power down the unit by pressing the power button on the front panel.
2. Locate the power supply on left side on the rear panel of the RDX 8000 unit, shown in section
“3.1 Rear panel
layout” on page 10
.
3. Remove the power cord on the rear panel of the unit.
4. Loosen the two thumbscrews located on the rear of the power supply using a #3 Phillips screwdriver or your
fingers.
5. Pull the power supply straight out of the unit.
6. To store or ship the removed power supply, repackage it in the original or replacement device packaging materi-
als.
2.1.2 Installing a power supply
1. Locate the power supply bay on left side on the rear panel of the RDX 8000 unit, shown in section
“3.1 Rear panel
layout” on page 10
.
2. Before installing the power supply, inspect the connectors on the power supply. Ensure that the connectors are
intact, free of any foreign objects, and have no cracks or deformed or bent contacts.
3. Insert the power supply on the alignment rails and push the power supply into the power supply bay until it seats
itself against the back of the unit.
Figure 54 — Installing a power supply
4. Tighten the two thumbscrews using a #3 Phillips screwdriver or your fingers to secure the power supply to the
unit.