4.3.1 A.Fill mode setting
In the Auto Fill (A.Fill) mode you can set the exposure of the remote flash from 3 stops below to 2
stops above the camera setting.
Note : The F number displayed on the remote flash will be the result of the Cameras F number
and the A.Fill setting. For example, if the camera is set to F8.0 and the A.Fill setting is –1, the
remote flash will display F5.6.
4.4 Man (Manual)
Light output is controlled by fixed power output of flash.
Use this mode if you want the most accurate and repeatable exposures possible.
4.4.1 Man mode setting
In Manual mode the power can be adjusted from 1/64 to 1/1 in third stop increments.
4.5 LINK
Light output is controlled by the sensor located on the Pilot. The F number and ISO information
comes from the camera.
This mode provides the accuracy of the Auto setting while eliminating the need to worry about
flash placement. No matter where the flash is placed the sensor located on the Pilot will ensure
that the correct exposure reaches the camera.
4.5.1 LINK mode setting
You can set the light output 3 stops below or 2 stops above the camera setting.
Note : There is only one LINK setting possible. If you have two or more remote flashes in LINK
mode they will share the same LINK setting.
4.6 OFF
Prevent the remote flash from firing.
5. Setting up a remote 5D-R
Qflash model 5d-R requires a Free X Wire receiver model FW7Q or FW8R.
If you are using an FW8R then you will also need an FW31 cable to connect the FW8R to the
Qflash.
Step 1
After connecting the Free X Wire to the Qflash. Connect the Qflash to a Turbo, Turbo SC, or
Turbo 2x2 and turn the power on.
Step 2
Set the channel on the Free X Wire to the channel you will be using on the Pilot.
Turn all four zones
on.
Step 3
Change the mode of the Qflash to
Wireless Group 1
or Wireless Group 2.
Note : Qflash 5d-R
does not support
R3
.
You may set up many flashes within a group. All flashes within a group will be set identically
from the Pilot.
There is no limit to the number of flashes for a group.
Step 4
Once you are done setting up the remotes, turn on the Pilot.
The Pilot will send mode and setting information to the remote flashes.
Note :
HSS is not supported when using a Qflash 5d-R as one of the remotes. Make sure that this
option is turned OFF.
6. Setting up a remote TRIO
Step 1
Connect the TRIO to a Turbo, Turbo SC, or Turbo 2x2 and turn the power on.
Step 2
Set the channel on the Free X Wire to the channel you will be using on the Pilot.
Step 3
Change the mode of the Qflash to
Remote Group 1, Remote Group 2,
or
Remote Group 3.
Note : If your TRIO does not support
R3
visit www.qtm.com for the latest TRIO software.
You may set up many flashes within a group. All flashes within a group will be set identically
from the Pilot.
There is no limit to the number of flashes for a group.
Step 4
Once you are done setting up the remotes, turn on the Pilot.
The Pilot will send mode and setting information to the remote flashes.
HSS is automatically selected for remotes. There is no need to select the HSS option.