background image



iLevel® Feature (Optional)

Your power chair may be equipped with the iLevel® feature that will be used in conjunction with your 
TRU-Balance® 3 Power Positioning System. The iLevel® feature is mounted on a Quantum power base 
for enhanced stability when the seating system is elevated.

There are certain situations, including some medical conditions, where the power chair user will need 
to practice operating the power chair equipped with iLevel® in the presense of a trained attendant.  A 
trained attendant can be defined as a family member or care professional specially trained in assisting 
a power chair user in various daily living activities.

As you begin using iLevel® during daily activities, you will probably encounter situations in which you 
will need some practice. Simply take your time and you will soon be in full and confident control.

Elevation (Seat Screen)

The iLevel® feature can be activated by selecting the elevating seat actuator.

To select and adjust the seat elevation using the Q-Logic 3 Controller:
1.  Push the On/Off and Mode Select Lever up once to power on the chair and the controller.
2.  Push the On/Off and Mode Select Lever up several times until the seat screen is displayed on the 

LCD or push the key 2 select button once to go directly to seat screen. 

See figure 1.

3.  Push the joystick to the left or right to cycle through to the elevating seat mode, this is illuminated on 

the actuator indicator. 

See figure 1

NOTE: If your Q-logic 3 settings are different than those described, contact your Quantum Rehab 

Provider.  Your Quantum Rehab Provider may have changed the programming of your Q-Logic 

3 Controller.

4.  When the elevating seat mode is selected, give a forward command to the joystick to adjust position  

in one direction or give a reverse command to the joystick to adjust position in the opposite direction.

5.  If you want to return to another profile, push up and release the On/Off and Mode Select Lever until 

you return to the desired drive profile.

To activate the iLevel® using a single switch:
1.  Press once and hold the single switch once to raise the seat and activate iLevel®.
2.  Press and hold the single switch to lower the seat.

NOTE: The iLevel® feature is automatically engaged when the power elevating seat is activated 

and the iLevel® indicator is displayed on your controller.  See figure 2.

The power chair should be used on an indoor, level surface, such as malls, offices, and/or medical 
facilities to activate iLevel®. Once the seating system actuator is started, the iLevel® boots inhibit 
movement on the front caster arms. The seating system can be reclined or tilted up to 20° while the 
iLevel® feature is activated.

Summary of Contents for Q-Logic 3

Page 1: ...Basic Operation Instructions...

Page 2: ...Key Controller Joystick Horn Button Light Button LCD Screen On Off and Mode Jacks Key 2 Select Button Left Turn Indicator Button Right Turn Indicator Button Drive Function Inhibit Key 1 Select Button...

Page 3: ...splay Battery Condition Meter LCD Screen Battery Condition Meter Mode Button On Off Button On Off Button Mode LED 4 Direction Navigation Key Joystick Charger Programmer Port Actuator Indicators Mode B...

Page 4: ...hite symbol on a blue dot with a white border PROHIBITED These actions are prohibited These actions should not be performed at any time or in any circumstances Performing a prohibited action can cause...

Page 5: ...tton 9 Light Button 9 Left Right Turn Indicator Button 9 LCD Screen 9 Drive Screen 10 Drive Profile Selection 11 Actuator Adjustment Seat Screen 11 iLevel Feature Optional 13 Settings Screen 15 Blueto...

Page 6: ...letely Read and follow the information in the owner s manual Avoid exposure to rain snow ice salt or standing water whenever possible Maintain and store in a clean and dry condition EMI RFI This produ...

Page 7: ...troller before you are seated in your power chair Always have assistance when you are being seated in your power chair Follow all of the procedures and heed the warnings as explained in your power cha...

Page 8: ...used to control the speed of the power chair To change the speed 1 Push the On Off and Mode Select Lever up once to power on the chair and the controller 2 To increase your speed turn the speed adjust...

Page 9: ...he left or right turn indicators To operate the turn indicators 1 Push the On Off and Mode Select Lever up once to power on the chair and the controller 2 Press the desired turn indicator button once...

Page 10: ...seat and or back angle increases a red light will indicate full drive lockout If your power chair is equipped with a seat lift a yellow light will indicate speed reduction as the seat is elevated To r...

Page 11: ...adjustment seat screen This function is disabled in drive mode in order to prevent unintended loss of function in your power chair Take caution when negotiating obstacles ramps and inclines Whenever...

Page 12: ...ting Seat Mode 4 Recline ELR ALR Mode both 5 Articulating Foot Platform 6 ALR ELR Mode both 1 5 7 ALR ELR Mode right 8 ALR ELR Mode left NOTE The Drive Function Inhibit status is affected only in the...

Page 13: ...2 select button once to go directly to seat screen See figure 1 3 Push the joystick to the left or right to cycle through to the elevating seat mode this is illuminated on the actuator indicator See...

Page 14: ...able or a desk Keep area clear prior to and during movement PROHIBITED Never use the iLevel outdoors on uneven terrain gravel hills or other uneven non compact terrain or in fields PROHIBITED Never us...

Page 15: ...ects 4 When the desired subject is highlighted on the settings screen push the joystick to the right to enter that subject NOTE At any time a left command will return to the previous menu Home Screen...

Page 16: ...ed on the settings screen push the joystick to the right to enter that subject NOTE At any time a left command will return to the previous menu After Display is highlighted a right command will show A...

Page 17: ...gs screen push the joystick to the right to enter that subject NOTE At any time a left command will return to the previous menu After Bluetooth operation is highlighted a right command will show This...

Page 18: ...ime a left command will return to the previous menu Display After Display is highlighted a right command will show Time After Set time is highlighted a right command will show To set time from the set...

Page 19: ...night 2 Push the joystick up or down to adjust brightness value will change 5 for every push of joystick 3 Push the joystick left to exit and accept setting Home Screen After Display is highlighted a...

Page 20: ...oller 1 Push the home button to access the home screen 2 Push the joystick to the right to access the Environmental Functions menu 3 Use the joystick to highlight the Bluetooth function you wish to en...

Page 21: ...Q Logic 3 to be programmed by a dealer of medical equipment through a paired Windows device Prog Access Econ w must be enabled to allow the dealer of medical equipment access to the Q Logic 3 paramete...

Page 22: ...able Environmental Functions 4 When the Mouse Connections subject is highlighted on the Auxiliary screen push the joystick to the right NOTE At any time a left command will return to the previous menu...

Page 23: ...function through the Environmental Functions Screen 1 Push the Home Screen button 2 Push the joystick right for Environmental Functions Screen 3 Push the joystick up or down through the available Envi...

Page 24: ...ety Guide for more information regarding EMI RFI Although we do not recommend using a cell phone while operating a power chair the system is capable of receiving and or making calls through a cell pho...

Page 25: ...ward to activate the desired actuator s On Off and Mode Jacks Allow for remote On Off and Mode switch installations Standby Select Menu The Standby Select Menu screen appears after the programmed time...

Page 26: ...e LCD Screen A color LCD display that may be equipped with built in infrared IR for remote control and with Bluetooth mouse control 4 Direction Navigation Key The up down arrows of the four direction...

Page 27: ...the joystick on the hand control and as an LED on the Attendant Control and Stand alone Joystick Or GREEN 100 50 YELLOW 49 25 RED 24 0 BATTERY CONDITION METER Figure 2 Battery Condition Meter Q Logic...

Page 28: ...or 1 output defect Error Motor 1 output defect Motor 1 error detected 1 Turn power off 2 Inspect motor connections 3 Turn power on 24 Motor 2 output defect Error Motor 2 output defect Motor 2 error de...

Page 29: ...ck not engaged Seek level ground Suspension lock not engaged 1 Seek level ground 2 Check suspension lock mechanism Care and Maintenance Refer to your power chair owner s manual for proper cleaning and...

Page 30: ......

Page 31: ......

Page 32: ...lia 20 24 Apollo Drive Hallam Victoria 3803 www quantumrehab com au New Zealand 38 Lansford Crescent Avondale Auckland New Zealand 1007 www pridemobility co nz Italy Via del Progresso ang Via del Lavo...

Reviews: