Quantum PX502 Chassis Repacking Instructions
Document 81-81453-02 A01
January 2006
4
Removing the Library from the Rack
3
From the back of the library, disconnect all power, Ethernet, and SCSI
cables from the library and note their locations for later reinstallation.
Warning:
This unit has more than one power supply cord.
Disconnect all power supply cords before servicing to
avoid electric shock.
4
To remove the library chassis from the rack (see
figure 1
):
Note:
Refer to the
PX502 Quick Start Guide
(PN 81-81292) for
additional PX502 rack mount information.
a
Loosen the captive screws securing the tape drives to the chassis and
remove the tape drive(s) from the back of the library.
b
Loosen the captive screw securing the power supplies to the chassis
and remove the power supplies from the back of the library.
c
Remove PHILLIPS® screws securing each side of the chassis to the
rack mounting rails and remove two Allen screws securing both
clamps on the back of the library.
d
Remove the library from the rack.
Warning:
At least two people are required to move the library
chassis.