Summary of Contents for Prism FC230

Page 1: ...ation 3 Key to Successful Configuration of the FC230 4 FC230 Router Configuration 4 Connect a Service PC to the Library 4 Start the FC230 Services Software 6 Upgrade the FC230 Firmware 7 Scan the SCSI...

Page 2: ...ATL P Series Library User s Guide Addendum Prism FC230 Router 6331121 03 Ver 3 Rel 2 August 2002 2 6207947 04aN 10...

Page 3: ...Series Library User s Guide Fibre Channel Description 0 Fibre Channel is a serial data transfer architecture for use with computers and mass storage devices Fibre Channel is rapidly emerging to challe...

Page 4: ...ow how many SCSI buses are present in the library SCSI devices are connected to each bus FC230 Router Configuration 0 The FC230 router configuration includes the following steps Connect a Service PC t...

Page 5: ...cable slot in the base of the library cabinet 5 Close the library back access panel 6 Connect the opposite end of the serial cable to the com port on a service PC 7 Turn on the PC 8 Bring up a termina...

Page 6: ...tings then power cycle the library 4 Press Enter when POST completes and Ready displays The PC is now in command line mode If this is an initial installation or a replacement FC230 board has been inst...

Page 7: ...en select Call Disconnect d From the HyperTerminal menu select File Properties Connect To tab Configure button e Set the baud rate to 115200 f From the HyperTerminal menu select Call Connect 3 At the...

Page 8: ...he SCSI Buses 0 Use the following procedure to confirm that the SCSI buses are cabled properly and the SCSI IDs are properly set as shown in figure 4 1 Connect the serial cable to the RJ 45 connector...

Page 9: ...for the Ready prompt before proceeding c Type firmwarerestart then press Enter The POST screen displays and the FC230 services software is ready for use 7 At the Ready prompt type scsitargets 0 then...

Page 10: ...ers must be preceded by 0 ex 0713 and hexadecimal numbers must be preceded by the C style 0x prefix ex 9x1FA4 Quoted strings are treated as a single parameter for any command that expects character in...

Page 11: ...fp fp fp Typing automap by itself distributes maps across all 3 ports BootFibreDelay Sets the time in seconds for the Fibre Channel bridge to wait before announcing its presence to the Fibre switch 30...

Page 12: ...level events are displayed The mask is a byte value with the following bit patterns corresponding to the currently supported reporting levels 0x01 Info general information 0x02 Warning unexpected situ...

Page 13: ...e Channel frame If the frame length is not specified the current frame length is displayed 2048 bytes set fcframelength 512 1024 2048 get fcframelength FcFullDuplex Enables disables full duplex commun...

Page 14: ...csibusystatus FcTargets Immediate Displays information about every FC device visible to a bridge operating in initiator mode fctargets fp FcWWName Reports the World Wide Name WWN of the referenced Fib...

Page 15: ...rts the current IP subnet mask assigned by the nameserver set IPSubnetMask xxx xxx xxx xxx get IPSubnetMask LicensedOption Enables disables a user defined licensed option none set licensedoption optio...

Page 16: ...mes RESERVED Performing a SaveConfiguration RestoreConfiguration or FcRestart RELEASES the FC230 so that other devices may access it When the FC230 services interface is reserved set commands are unav...

Page 17: ...isabled get scsiportresetonstartup sb ScsiPortSelTimeout Show the time msec that the router waits for a response from a SCSI device on the selected port after a selection request 256 msec set scsiport...

Page 18: ...r subsequent SCSI devices mapped to the FC bridge disabled set speedwritedefault enabled disabled get speedwritedefault Temperature Report the unit temperature in degrees C get temperature VerboseMode...

Page 19: ...ds Any field that does not contain valid data is filled in with 00 get SCError CmdNumber XCStatus Allows the user to poll for the status of Extended Copy commands issued to the FC The CmdNumber field...