FC230 Router Configuration
Confirm the new firmware revision is displayed in the
HyperTerminal screen as the software comes ready. Wait for the
Ready
prompt.
9
Reset the FC230 and the service PC back to 9600 baud:
a
At the
Ready
prompt, type
set serialportbaudrate 9600
and
then press
<Enter>
.
b
Type
saveconfiguration
, then press
<Enter>
.
Wait for a new
Ready
prompt.
c
From the HyperTerminal menu, located at the top of the screen,
select
Call/Disconnect
.
d
From the HyperTerminal menu select
File/Properties/
Connect To tab/Configure button
.
e
Set the baud rate to 9600.
f
From the HyperTerminal menu select
Call/Connect
.
Scan the SCSI Buses
0
Use the following procedure to confirm that the SCSI buses are cabled
properly and the SCSI IDs are properly set, as shown in
1
Connect the serial cable to the RJ-45 connector of the first FC230
board in the library.
2
Cycle power on the library to start the FC230 services software.
3
At the
Ready
prompt:
a
Type
scsitargets 0
, then press
<Enter>
as shown in
.
This command scans and displays all SCSI devices found on
SCSI bus 0 - the robotics controller and drives 0 and 1.
b
Type
scsitargets 1
, then press
<Enter>
as shown in
.
Scans bus 1 - displays drives 2 and 3.
c
Type
scsitargets 2
, then press
<Enter>.
Scans bus 2 - displays drives 4 and 5.
d
Type
scsitargets 3
, then press
<Enter>.
Scans bus 3 - displays drives 6 and 7.
4
Move the serial cable to the RJ-45 connector of the second FC230
board in the library.
5
Press
<Enter>
.
Ready
is displayed on the screen. The PC is now in command line
mode.